ALERT REPORT: Week 10 Monday February 28, 2011 - Sunday March 6, 2011 (059j - 065j) Completed: Sunday, March 6, 2011 Operator: Kevin Anderson Co-op Student: Natalie Dierx Visitors: Sangeeta Sharma, Desi Toom-Sauntry, Richard Leaitch (Richard arrived 062j) ***********Highlights of the Week*************** *062j Richard arrives to calibrate new aerosols equipment at lab. Byron departs. *064j Sangeeta thoughtfully (and rather stealthily) asks the cooks to bake a surprise birthday cake for me - the second birthday I've celebrated in Alert in the past 7 years! **********Highlights of the Week*************** THINGS WE NEED: *The items will be left on the list until they are physically received in Alert* Please note: Inventories are current as of the week the report is written unless stated otherwise. -New Oscilloscope AEROSOL PROGRAM O.K. Aethalometer 1 *261j, 2009 -Aethalometer unit removed upon completion of final filter change at 16:00 UTC -OFFLINE Aethalometer 2(Magee Scientific) O.K. PSAP Program O.K. IGLOOLIK Sampler O.K. Nephelometer O.K. Black carbon filter pack O.K. CNC Counter O.K. Alert High Volume Sampler O.K. ALERT HI-VOL UNIT Last Blank: 354j, 2010 11 filter(s) in inventory Received: Case # in: Sent out: Case # out: O.K. LAB HI-VOL UNIT *095j, 2010 -Lab Hi-Vol filters now being counted for use with Alert Hi-Vol as sampling ceased as of 088j Last Blank: 074j, 2010 0 filter(s) in inventory Received: Case # in: Sent out: Case # out: O.K. Toxics Sampler 37 PUF filters canisters, 9 Blank(s) canisters, 47 GFF(s) 17 Toxics case(s) remaining in inventory Last blank: 059j. O.K. PS-1 PUF Sampler Last blank: 326j, 2010 Last flow calibration: 326j, 2010 11 filters remaining in inventory 11 cartridges remaining in inventory O.K. GAPS Network Passive sampling program O.K. FTAS O.K. MET PROGRAM O.K Ambient Temperature Sensor [Campbell 107F] O.K. Stevenson Screen and Dew Cells O.K. Tall Tower 10m and Lab Platform 10m RM Young Wind Sensors O.K. GAS PROGRAM NDIR O.K. PICARRO O.K. CAPMoN Ozone TEI 49C #49C-73452-373 O.K. CAPMoN Ozone Teco #347 - Offline CAPMoN Ozone Calibration Unit O.K. CFC 11,12,13 GC *348j, 2009 -Pump unplugged as instrument sampling was ceased at 14:29 UTC -OFFLINE CH4/CO2/CO GC *259j Flame out; after attempts to turn back on Robert Kessler concluded that the EPC circuit board must be damaged. Turned off FID station and Thomas pump -OFFLINE Complete Gas Tank Inventory ***Please see Inventory 2011.xls checksheet attached to weekly report email MERCURY PROGRAM Ambient air (007): *059j -Ar tank change @ 15:29 UTC -NOTE that 007 was not manually restarted immediately after Ar tank change (operator error); instrument was restarted @ 18:56 UTC O.K. Ambient Air (070): -OFFLINE RGM Unit, 1130 0016, 2537A (012): *059j -Ar tank change @ 15:29 UTC -RGM on zero air (012 in idle mode) @ 17:39 UTC for the following changes: Denuder (OFF: PCG444; ON: PCG555) RPF glassware (OFF: C; ON: B) Impactor (changed) Teflon zero filter (1130 unit) Quartz sample filter (1130 unit) Soda lime trap -Desorb and heaters manually ON @ 18:22 UTC -heaters OFF and cooling ON @ 18:48 UTC -system back on AUTO @ 18:58 UTC O.K. DENUDER INVENTORY = 1 case(s), 0 tube(s): 1 denuder(s). O.K. RDMQ 2009QC for 007 complete up to 183j 2009QC for 012 complete up to 138j OTHER PROGRAMS Health Canada Precipitation Collector Changed: 064j, 2011 Inventory: 7 month(s) Health Canada Thermo-Luminescence Detector Changed:365j, 2010 Brewers 019: *062j -The following maintenance was performed between 19:20 - 21:30 UTC: -installed serial-to-USB converter -performed various physical checks on cards and ribbon connectors in Brewer to identify connection issues -019 connected briefly, but problems persist OFFLINE 029: *062j -The following maintenance was performed between 19:20 - 21:30 UTC: -installed serial-to-USB converter -Brewer will go through azimuth zeroing and other initialization parameters, but will not run on schedule (connection fails after putting Brewer on schedule); more trouble-shooting for 029 planned for next suitable day (whether permitting) O.K. 194: O.K. Permafrost *063j Monthly permafrost checks completed O.K. BSRN Solar Radiation Program O.K. INTERNATIONAL PROGRAMS Bi-weekly 14C/12C-CO2 Sample for U. of Heidelberg Last Sample: 052j Inventory: 32 bottle(s), 64 week(s) O.K. Radon Monitor Last filter change: Day 031j *063j -radon pump mistakenly unplugged @ ~ 15:00 UTC (while aerosols personnel were at lab & unplugging aerosols pumps for maintenance on aerosols system); pump plugged back in and running @ 15:30 UTC. *064j -found "range check error" showing on Radon computer @ 19:30 UTC -tried to restart instrument and computer a number of times before noticing the full restart procedure posted in lab -restarted instrument and radon monitor program @ 20:03 UTC O.K. DOAS System *059j -Auto acquisition stopped and plastic cap on telescope @ 20:17 UTC -Calibration sequence started @ 20:22 UTC -Cap off and Auto Acquisition restarted @ 20:36 UTC *056j -Auto acquisition stopped and plastic cap on telescope @ 14:38 UTC -Calibration sequence started @ 14:40 UTC -Hg lamp calibration @ 15:07 UTC (Int Time: 1650 msec; Scans: 1000) -Plastic cap removed and Auto Acquisition re-started @ 16:13 UTC O.K. NOAA SEARCH O.K. NOAA ETL O.K. ***************FLASKING REPORT************** Sampling Conditions: -32.0 C, 1.2 m/s, R.H. 41.4%, 993.0 mbar. Flasks sampled: 03/03/2011 (062j) Scripps 5L glass greased stopcock, evacuated: I199, I200 Inventory 13 box(es), 13 week(s) Japanese Halocarbon, steel 5L: 7919, 7925 Inventory 2 box(es), 2 week(s) NOAA 2.5L 007 pressurized: 1843-99, 1844-99 Inventory 5 box(es), 10 week(s) MSC 2L glass double valve pressurized: P2-59, P2-60 Inventory 6 box(es), 12 week(s) NOAA stainless steel 850mL/2.5L pressurized: 5073L, 5074R Inventory 5 box(es), 5 week(s) CSIRO/MSC 2L glass, pressurized: P2-404, P2-405 Inventory 2 box(es), 8 week(s) SCRIPPS 3 X 5L Oxygen: 491, 163, 480 Inventory 14 box(es), 28 week(s) PRL VOC, pressurized: AL034 Inventory 15 flask(s), 15 week(s) U of Heidelberg 1L glass pressurized: 22-Q95, 22-Q97 Inventory 22 flask(s), 11 week(s) Max Planck Institute - BGC: TT-603, TT-604, TT-610 Inventory 10 case(s), 10 week(s) French Program: 2607-25, 2608-25 Inventory 24 Flask(s), 12 week(s) COMPUTERS *052j -Kiosk UPS continues to beep intermittently (ceases upon pressing ESC on UPS); probably needs to be replaced O.K. TRANSPORTATION Fuel Consumption, for February: 173 L GMC (EC Rider) O.K. 2006 Ford (Red Rover) O.K. 2009 Ford (Brown Betty) O.K. BUILDINGS TX O.K. Lab O.K. SHIPPING: Shipping Received: Shipping Sent: -triwall 2 x NOAA SS (5192L, 5193R; 5129L, 5130R) FTAS (04/01/2011 - 02/02/2011) HiVol case (11/01/17 - 11/02/14) Toxics case (2011/01/31 - 2011/02/14) Scripps 3x5 (268, 406, 440) ICP blue (P2-412, P2-413, P2-414, P2-415) STB orange (P2-77, P2-78, P2-79, P2-80) 2 x Scripps 5L (I197, I198, I201, I202) NOAA 007 (6047-66, 6048-66, 2695-99, 2696-99) MPI (TT-463, TT-465, TT-471) MAIL Mail Received: Mail Sent: