ALERT REPORT: Week 17 Monday April 18, 2011 - Sunday April 24, 2011 (108j - 114j) Completed: Monday, April 25, 2011 Operator: Joshua Benmergui Co-op Student: Natalie Dierx Visitors: Sangeeta Sharma, Ralph Steabler, Byron Felske, Kevin Anderson ***********Highlights of the Week*************** **********Highlights of the Week*************** THINGS WE NEED: *The items will be left on the list until they are physically received in Alert* Please note: Inventories are current as of the week the report is written unless stated otherwise. AEROSOL PROGRAM *108j Impactor valve closed 14:31-14:45 UTC for 1 um impactor servicing *105j Aerosols system zero 17:18 - 18:24 UTC O.K. Aethalometer 2(Magee Scientific) O.K. PSAP Program O.K. IGLOOLIK Sampler O.K. Nephelometer *108j Span check performed @ 15:14 UTC -Ave error: 2.47% O.K. ACSM O.K. Black carbon filter pack *108j Black carbon filter pack changed Off: AL110411T-56079-14 / AL110411Tef Time: 15:50 UTC Flow: 30.0 On: AL110418T-56079-15 / AL110418Tef Time: 14:50 UTC Flow: 31.0 O.K. CNC Counter O.K. Alert High Volume Sampler O.K. ALERT HI-VOL UNIT Last Blank: 094j 13 filter(s) in inventory Received: Case # in: Sent out: Case # out: O.K. LAB HI-VOL UNIT *095j, 2010 -Lab Hi-Vol filters now being counted for use with Alert Hi-Vol as sampling ceased as of 088j Last Blank: 074j, 2010 0 filter(s) in inventory Received: Case # in: Sent out: Case # out: O.K. Toxics Sampler 30 PUF filters canisters, 8 Blank(s) canisters, 40 GFF(s) 15 Toxics case(s) remaining in inventory Last blank: 087j. O.K. PS-1 PUF Sampler Last blank: 080j, 2011 Last flow calibration: 080j, 2011 16 filters remaining in inventory 16 cartridges remaining in inventory O.K. GAPS Network Passive sampling program O.K. FTAS O.K. MET PROGRAM O.K Ambient Temperature Sensor [Campbell 107F] O.K. Stevenson Screen and Dew Cells O.K. Tall Tower 10m and Lab Platform 10m RM Young Wind Sensors O.K. GAS PROGRAM NDIR O.K. PICARRO O.K. CAPMoN Ozone TEI 49C #49C-73452-373 O.K. CAPMoN Ozone Teco #347 - Offline CAPMoN Ozone Calibration Unit O.K. CFC 11,12,13 GC *348j, 2009 -Pump unplugged as instrument sampling was ceased at 14:29 UTC -OFFLINE CH4/CO2/CO GC *259j Flame out; after attempts to turn back on Robert Kessler concluded that the EPC circuit board must be damaged. Turned off FID station and Thomas pump -OFFLINE Complete Gas Tank Inventory ***Please see Inventory 2011.xls checksheet attached to weekly report email MERCURY PROGRAM Ambient air (007): O.K. Ambient Air (070): -OFFLINE RGM Unit, 1130 0016, 2537A (012): *108j The following changes were made between 15:44-16:03 UTC -Denuder changed: Out: PLCC In: PL100 -Impactor frit flipped -Quartz sample line filter changed -RPF glassware changed: Out: C In: A -Soda lime trap changed -Zero line filter changed O.K. DENUDER INVENTORY = 3 case(s), 0 tube(s): 10 denuder(s). O.K. RDMQ 2009QC for 007 complete up to 183j 2009QC for 012 complete up to 138j OTHER PROGRAMS Health Canada Precipitation Collector Changed: 094j, 2011 Inventory: 5 month(s) Health Canada Thermo-Luminescence Detector Changed:101j Brewers 019: OFFLINE 029: Constantly goes to "Brewer reset @ ..." O.K. 194: *108j found over travel switch flipped during drive plate cleaning. Flipped back, set to al1mk3. OFFLINE Permafrost O.K. BSRN Solar Radiation Program O.K. INTERNATIONAL PROGRAMS Bi-weekly 14C/12C-CO2 Sample for U. of Heidelberg *110j Noticed a little NaOH dripping from the end of the glassware. Adjusted glassware to stop leak. Last Sample: 101j Inventory: 29 bottle(s), 58 week(s) O.K. Radon Monitor Last filter change: Day 094j O.K. DOAS System *108j Auto calibration sequence run @ 12:30 UTC *110j Auto Calibration sequence run @ 12:36 UTC *112j Hg Calibration started @ 17:37 UTC Auto Calibration Sequence started @ 18:02 UTC O.K. NOAA SEARCH O.K. NOAA ETL O.K. ***************FLASKING REPORT************** Sampling Conditions: -24.1 C, 2 m/s, R.H. 50%, 989.6 mbar. Flasks sampled: 20/04/2011 (110j) Scripps 5L glass greased stopcock, evacuated: I-205, I-206 Inventory 9 box(es), 9 week(s) Japanese Halocarbon, steel 5L: NA Inventory 5 box(es), 5 week(s) NOAA 2.5L 007 pressurized: 3719-99, 3720-99, -99, -99 Inventory 9 box(es), 9 week(s) MSC 2L glass double valve pressurized: P2-69, P2-70 Inventory 7 box(es), 14 week(s) NOAA stainless steel 850mL/2.5L pressurized: 4637L, 4659R Inventory 8 box(es), 8 week(s) CSIRO/MSC 2L glass, pressurized: P2-, P2- Inventory 5 box(es), 20 week(s) SCRIPPS 3 X 5L Oxygen: NA Inventory 11 box(es), 22 week(s) PRL VOC, pressurized: AL033 Inventory 15 flask(s), 15 week(s) U of Heidelberg 1L glass pressurized: 22-Q113, 22-Q116 Inventory 52 flask(s), 26 week(s) Max Planck Institute - BGC: TT-, TT-, TT- Inventory 7 case(s), 7 week(s) French Program: 2413-25, 3296-25 Inventory 21 Flask(s), 10.5 week(s) COMPUTERS O.K. TRANSPORTATION Fuel Consumption, for April: 232 L GMC (EC Rider) O.K. 2006 Ford (Red Rover) O.K. 2009 Ford (Brown Betty) O.K. BUILDINGS TX O.K. Lab O.K. SHIPPING: Shipping Received: Shipping Sent: *111j Triwall: Hi-vol case (2011/03/28-2011/04/11) Helium Isotope Flask Scripps 5L x2 (I-203,I-204,I-205,I-206) STB (P2-97,P2-98,P2-99,P2-100) Scripps 3x5 (351,220,513) ICP (P2-416,P2-417,P2-418,P2-600) NOAA 007 (981-99,982-99,3719-99,3720-99) NOAA SS x2 (4657L,4628R,4637L,4659R) PRL (AL003,AL005,AL015,AL029,AL033,AL025) Denuders x2 MAIL Mail Received: Mail Sent: