eurqclog.20050903.000000.txt Data Quality Summary for Eureka SEARCH Research Station Summary created: Sun Sep 4 00:31:20 2005 Value Interpretation -1: No assessment preformed. 0: All values out of range. 1: Some values in and out of range. 2: All data present and all values in range. ----------------------------------------------------------- STATUS FLAGS ----------------------------------------------------------- MMCR: Millimeter Cloud Radar Instrument Status: 1 Data Continuity: 2 Data Quality: -1 MWR: Microwave Radiometer Instrument Status: -1 Data Continuity: -1 Data Quality: -1 AHSRL: Arctic High Spectral Resolution Lidar Instrument Status: -1 Data Continuity: 1 Data Quality: -1 DMS: Data Management System Filesystem Size Used Avail Use% Mounted on /dev/sda1 2.2T 166G 1.9T 8% /data /dev/sdd1 230G 93M 218G 1% /media/usbdisk /dev/hda1 4.0G 307M 3.5G 9% / ------------------------------------------------------------ --------------- ERROR SUMMARIES --------------- MMCR: Instrument Status: 1 20052460100Health.txt: UPSBatteryVoltage: 116/116 out of range ( 13.25 to 14.50), Mean: 12.16, StdDev: 0.01 20052460200Health.txt: UPSBatteryVoltage: 116/116 out of range ( 13.25 to 14.50), Mean: 12.16, StdDev: 0.02 20052460300Health.txt: UPSBatteryVoltage: 116/116 out of range ( 13.25 to 14.50), Mean: 12.15, StdDev: 0.02 20052460400Health.txt: UPSBatteryVoltage: 116/116 out of range ( 13.25 to 14.50), Mean: 12.15, StdDev: 0.01 20052460500Health.txt: UPSBatteryVoltage: 116/116 out of range ( 13.25 to 14.50), Mean: 12.14, StdDev: 0.02 20052460600Health.txt: UPSBatteryVoltage: 115/115 out of range ( 13.25 to 14.50), Mean: 12.12, StdDev: 0.02 20052460700Health.txt: UPSBatteryVoltage: 115/115 out of range ( 13.25 to 14.50), Mean: 12.13, StdDev: 0.02 20052460800Health.txt: UPSBatteryVoltage: 116/116 out of range ( 13.25 to 14.50), Mean: 12.12, StdDev: 0.02 20052460900Health.txt: UPSBatteryVoltage: 116/116 out of range ( 13.25 to 14.50), Mean: 12.11, StdDev: 0.01 20052461000Health.txt: UPSBatteryVoltage: 116/116 out of range ( 13.25 to 14.50), Mean: 12.12, StdDev: 0.02 20052461100Health.txt: UPSBatteryVoltage: 116/116 out of range ( 13.25 to 14.50), Mean: 12.11, StdDev: 0.01 20052461200Health.txt: UPSBatteryVoltage: 116/116 out of range ( 13.25 to 14.50), Mean: 12.11, StdDev: 0.03 20052461300Health.txt: UPSBatteryVoltage: 115/115 out of range ( 13.25 to 14.50), Mean: 12.15, StdDev: 0.02 20052461400Health.txt: UPSBatteryVoltage: 116/116 out of range ( 13.25 to 14.50), Mean: 12.13, StdDev: 0.03 20052461500Health.txt: UPSBatteryVoltage: 116/116 out of range ( 13.25 to 14.50), Mean: 12.12, StdDev: 0.02 20052461600Health.txt: UPSBatteryVoltage: 116/116 out of range ( 13.25 to 14.50), Mean: 12.13, StdDev: 0.03 20052461700Health.txt: UPSBatteryVoltage: 115/115 out of range ( 13.25 to 14.50), Mean: 12.14, StdDev: 0.02 20052461800Health.txt: UPSBatteryVoltage: 115/115 out of range ( 13.25 to 14.50), Mean: 12.11, StdDev: 0.03 20052461900Health.txt: UPSBatteryVoltage: 116/116 out of range ( 13.25 to 14.50), Mean: 12.12, StdDev: 0.02 20052462000Health.txt: UPSBatteryVoltage: 115/115 out of range ( 13.25 to 14.50), Mean: 12.10, StdDev: 0.02 20052462100Health.txt: UPSBatteryVoltage: 116/116 out of range ( 13.25 to 14.50), Mean: 12.11, StdDev: 0.03 20052462200Health.txt: UPSBatteryVoltage: 116/116 out of range ( 13.25 to 14.50), Mean: 12.09, StdDev: 0.02 20052462300Health.txt: UPSBatteryVoltage: 115/115 out of range ( 13.25 to 14.50), Mean: 12.15, StdDev: 0.03 AHSRL: Data Continuity: 1 Data recovery: 93.9% DMS: RAID Status from dmesg 3w-9xxx: scsi0: Found a 3ware 9000 Storage Controller at 0xfb200000, IRQ: 201. 3w-9xxx: scsi0: Firmware FE9X 2.04.00.005, BIOS BE9X 2.03.01.047, Ports: 12. 3w-9xxx: scsi0: ERROR: (0x03:0x0104): SGL entry has illegal length:address=0x3678C000, length=0xFF, cmd=X. ---------------------------------------------------------