eurqclog.20060119.000000.txt Data Quality Summary for Eureka SEARCH Research Station Summary created: Fri Jan 20 00:31:12 2006 Value Interpretation -1: No assessment preformed. 0: All values out of range. 1: Some values in and out of range. 2: All data present and all values in range. ----------------------------------------------------------- STATUS FLAGS ----------------------------------------------------------- MMCR: Millimeter Cloud Radar Instrument Status: 1 Data Continuity: 2 Data Quality: -1 MWR: Microwave Radiometer Instrument Status: -1 Data Continuity: -1 Data Quality: -1 AHSRL: Arctic High Spectral Resolution Lidar Instrument Status: -1 Data Continuity: 2 Data Quality: -1 DMS: Data Management System Filesystem Size Used Avail Use% Mounted on /dev/sda1 2.2T 877G 1.2T 42% /data /dev/sdc1 230G 32G 187G 15% /media/usbdisk /dev/sdb1 230G 5.9G 212G 3% /media/usbdisk1 ------------------------------------------------------------ --------------- ERROR SUMMARIES --------------- MMCR: Instrument Status: 1 20060190100Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: 2.04, StdDev: 0.37 20060190110Health.txt: humidity (indoor): 5/5 out of range ( 10.00 to 75.00), Mean: 2.34, StdDev: 0.41 20060190110Health.txt: UPSBatteryVoltage: 2/17 out of range ( 13.25 to 14.50), Mean: 13.24, StdDev: 0.44 20060190200Health.txt: humidity (indoor): 20/20 out of range ( 10.00 to 75.00), Mean: -0.27, StdDev: 0.30 20060190200Health.txt: UPSInputVoltage : 1/81 out of range (114.00 to 126.00), Mean: 117.12, StdDev: 13.18 20060190200Health.txt: UPSOutputVoltage: 1/81 out of range (114.00 to 126.00), Mean: 119.88, StdDev: 13.49 20060190200Health.txt: UPSBatteryVoltage: 6/81 out of range ( 13.25 to 14.50), Mean: 13.17, StdDev: 1.48 20060190300Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.27, StdDev: 0.31 20060190400Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.25, StdDev: 0.31 20060190500Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.13, StdDev: 0.22 20060190600Health.txt: humidity (indoor): 28/28 out of range ( 10.00 to 75.00), Mean: -0.16, StdDev: 0.33 20060190700Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.17, StdDev: 0.30 20060190800Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.34, StdDev: 0.32 20060190900Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.19, StdDev: 0.27 20060191000Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.12, StdDev: 0.31 20060191100Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.22, StdDev: 0.28 20060191200Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.19, StdDev: 0.30 20060191300Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.13, StdDev: 0.32 20060191400Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.27, StdDev: 0.52 20060191500Health.txt: humidity (indoor): 28/28 out of range ( 10.00 to 75.00), Mean: -0.19, StdDev: 0.41 20060191600Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.20, StdDev: 0.38 20060191700Health.txt: humidity (indoor): 28/28 out of range ( 10.00 to 75.00), Mean: -0.21, StdDev: 0.28 20060191800Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.24, StdDev: 0.31 20060191900Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.35, StdDev: 0.37 20060192000Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.30, StdDev: 0.44 20060192100Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.19, StdDev: 0.38 20060192200Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.22, StdDev: 0.25 20060192300Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.24, StdDev: 0.34 DMS: RAID Status from dmesg 3w-9xxx: scsi0: Found a 3ware 9000 Storage Controller at 0xfb200000, IRQ: 201. 3w-9xxx: scsi0: Firmware FE9X 2.04.00.005, BIOS BE9X 2.03.01.047, Ports: 12. 3w-9xxx: scsi0: ERROR: (0x03:0x0104): SGL entry has illegal length:address=0x37044000, length=0xFF, cmd=X. 3w-9xxx: scsi0: ERROR: (0x03:0x0104): SGL entry has illegal length:address=0x35FA0000, length=0xFF, cmd=X. ---------------------------------------------------------