eurqclog.20060418.000000.txt Data Quality Summary for Eureka SEARCH Research Station Summary created: Wed Apr 19 01:21:02 2006 Value Interpretation -1: No assessment preformed. 0: All values out of range. 1: Some values in and out of range. 2: All data present and all values in range. ----------------------------------------------------------- STATUS FLAGS ----------------------------------------------------------- MMCR: Millimeter Cloud Radar Instrument Status: 1 Data Continuity: 2 Data Quality: -1 MWR: Microwave Radiometer Instrument Status: -1 Data Continuity: -1 Data Quality: -1 AHSRL: Arctic High Spectral Resolution Lidar Instrument Status: -1 Data Continuity: 2 Data Quality: -1 DMS: Data Management System Filesystem Size Used Avail Use% Mounted on /dev/sda1 2.2T 1.4T 684G 68% /data /dev/sdc1 230G 93M 218G 1% /media/usbdisk /dev/sdb1 230G 118G 101G 54% /media/usbdisk1 ------------------------------------------------------------ --------------- ERROR SUMMARIES --------------- MMCR: Instrument Status: 1 20061080100Health.txt: humidity (indoor): 28/28 out of range ( 10.00 to 75.00), Mean: -0.33, StdDev: 0.38 20061080200Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.22, StdDev: 0.28 20061080300Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.22, StdDev: 0.28 20061080400Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.25, StdDev: 0.25 20061080500Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.25, StdDev: 0.28 20061080600Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.25, StdDev: 0.28 20061080700Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.25, StdDev: 0.25 20061080800Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.20, StdDev: 0.24 20061080900Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.24, StdDev: 0.34 20061081000Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.34, StdDev: 0.29 20061081200Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.25, StdDev: 0.28 20061081300Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.24, StdDev: 0.28 20061081400Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.24, StdDev: 0.28 20061081500Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.29, StdDev: 0.46 20061081600Health.txt: rf cud tx +12V: 3/9 out of range ( 11.40 to 12.60), Mean: 11.42, StdDev: 0.05 20061081600Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.22, StdDev: 0.31 20061081700Health.txt: rf cud tx +12V: 5/9 out of range ( 11.40 to 12.60), Mean: 11.35, StdDev: 0.26 20061081700Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.25, StdDev: 0.28 20061081800Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.27, StdDev: 0.28 20061081900Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.15, StdDev: 0.26 20061082000Health.txt: humidity (indoor): 28/28 out of range ( 10.00 to 75.00), Mean: -0.30, StdDev: 0.36 20061082100Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.30, StdDev: 0.38 20061082200Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.20, StdDev: 0.31 20061082300Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.19, StdDev: 0.24 DMS: RAID Status from dmesg 3w-9xxx: scsi0: Found a 3ware 9000 Storage Controller at 0xfb200000, IRQ: 201. 3w-9xxx: scsi0: Firmware FE9X 2.04.00.005, BIOS BE9X 2.03.01.047, Ports: 12. 3w-9xxx: scsi0: ERROR: (0x03:0x0104): SGL entry has illegal length:address=0x3713E000, length=0xFF, cmd=X. 3w-9xxx: scsi0: ERROR: (0x03:0x0104): SGL entry has illegal length:address=0x36368000, length=0xFF, cmd=X. 3w-9xxx: scsi0: AEN: ERROR (0x04:0x0002): Degraded unit detected:unit=0, port=2. 3w-9xxx: scsi0: AEN: INFO (0x04:0x000B): Rebuild started:unit=0. 3w-9xxx: scsi0: AEN: INFO (0x04:0x003B): Background rebuild paused:unit=0. 3w-9xxx: scsi0: AEN: INFO (0x04:0x000B): Rebuild started:unit=0. 3w-9xxx: scsi0: AEN: INFO (0x04:0x0005): Background rebuild done:unit=0. 3w-9xxx: scsi0: AEN: ERROR (0x04:0x0002): Degraded unit detected:unit=0, port=2. 3w-9xxx: scsi0: AEN: INFO (0x04:0x000B): Rebuild started:unit=0. 3w-9xxx: scsi0: AEN: INFO (0x04:0x0005): Background rebuild done:unit=0. ---------------------------------------------------------