eurqclog.20070709.000000.txt Data Quality Summary for Eureka SEARCH Research Station Summary created: Tue Jul 10 13:55:58 2007 Value Interpretation -1: No assessment preformed. 0: All values out of range. 1: Some values in and out of range. 2: All data present and all values in range. ----------------------------------------------------------- STATUS FLAGS ----------------------------------------------------------- MMCR: Millimeter Cloud Radar Instrument Status: 1 Data Continuity: 1 Data Quality: -1 MWR: Microwave Radiometer Instrument Status: -1 Data Continuity: -1 Data Quality: -1 AHSRL: Arctic High Spectral Resolution Lidar Instrument Status: -1 Data Continuity: 1 Data Quality: -1 PAERI: Polar Atmos. Emitted Radiance Interferometer Instrument Status: -1 Data Continuity: -1 Data Quality: -1 DMS: Data Management System Filesystem Size Used Avail Use% Mounted on /dev/sda1 2.2T 1.7T 417G 81% /data /dev/sdb1 230G 89G 130G 41% /media/usbdisk /dev/sdc1 230G 93M 218G 1% /media/usbdisk1 ------------------------------------------------------------ --------------- ERROR SUMMARIES --------------- MMCR: Instrument Status: 1 20071901800Health.txt: temperature (indoor): 3/29 out of range ( 5.00 to 28.00), Mean: 26.47, StdDev: 1.05 20071901900Health.txt: temperature (indoor): 6/29 out of range ( 5.00 to 28.00), Mean: 27.19, StdDev: 1.09 20071901947Health.txt: temperature (indoor): 7/23 out of range ( 5.00 to 28.00), Mean: 27.78, StdDev: 0.84 MMCR: Data Continuity: 1 Data recovery: 82.4% AHSRL: Data Continuity: 1 Data recovery: 77.3% DMS: RAID Status from dmesg 3w-9xxx: scsi0: Found a 3ware 9000 Storage Controller at 0xfb200000, IRQ: 201. 3w-9xxx: scsi0: Firmware FE9X 2.04.00.005, BIOS BE9X 2.03.01.047, Ports: 12. ---------------------------------------------------------