eurqclog.20080822.000000.txt Data Quality Summary for Eureka SEARCH Research Station Summary created: Sat Aug 23 00:52:28 2008 Value Interpretation -1: No assessment preformed. 0: All values out of range. 1: Some values in and out of range. 2: All data present and all values in range. ----------------------------------------------------------- STATUS FLAGS ----------------------------------------------------------- MMCR: Millimeter Cloud Radar Instrument Status: 1 Data Continuity: 2 Data Quality: -1 MWR: Microwave Radiometer Instrument Status: 2 Data Continuity: 2 Data Quality: 1 AHSRL: Arctic High Spectral Resolution Lidar Instrument Status: -1 Data Continuity: -1 Data Quality: -1 PAERI: Polar Atmos. Emitted Radiance Interferometer Instrument Status: -1 Data Continuity: -1 Data Quality: -1 SON0: Sonic Anemometer #0 Instrument Status: -1 Data Continuity: 1 Data Quality: 2 SON1: Sonic Anemometer #1 Instrument Status: -1 Data Continuity: -1 Data Quality: -1 LICOR: Licor Measurements Instrument Status: -1 Data Continuity: 1 Data Quality: 1 TOWERMET: Flux Tower Meteorological Measurements Instrument Status: -1 Data Continuity: -1 Data Quality: -1 DMS: Data Management System Filesystem Size Used Avail Use% Mounted on /dev/sda1 2.2T 1.7T 449G 79% /data /dev/sdb1 230G 93M 218G 1% /media/usbdisk /dev/sdc1 230G 97G 121G 45% /media/usbdisk1 ------------------------------------------------------------ --------------- ERROR SUMMARIES --------------- MMCR: Instrument Status: 1 20082350400Health.txt: UPSOutputCurrent: 1/120 out of range ( 0.00 to 10.00), Mean: 5.52, StdDev: 0.64 20082351100Health.txt: UPSInputVoltage : 1/120 out of range (108.00 to 126.00), Mean: 119.02, StdDev: 11.05 20082351100Health.txt: UPSOutputVoltage: 1/120 out of range (114.00 to 126.00), Mean: 117.01, StdDev: 10.87 20082351100Health.txt: UPSOutputCurrent: 1/120 out of range ( 0.00 to 10.00), Mean: 5.49, StdDev: 0.64 20082351100Health.txt: UPSBatteryVoltage: 1/120 out of range ( 24.00 to 58.00), Mean: 52.85, StdDev: 4.96 20082351700Health.txt: UPSInputVoltage : 2/120 out of range (108.00 to 126.00), Mean: 117.56, StdDev: 15.51 20082351700Health.txt: UPSOutputVoltage: 2/120 out of range (114.00 to 126.00), Mean: 116.34, StdDev: 15.35 20082351700Health.txt: UPSOutputCurrent: 2/120 out of range ( 0.00 to 10.00), Mean: 5.63, StdDev: 0.88 20082351700Health.txt: UPSBatteryVoltage: 2/120 out of range ( 24.00 to 58.00), Mean: 52.39, StdDev: 6.98 MMCR: Data Continuity: 2 Data recovery: 100.0% MWR: Data Continuity: 2 Data recovery: 99.9% MWR: Data Quality: 1 TB_30.000: 299/5683 out of range [0-300 K] SONIC0: Data Continuity: 1 Data recovery: 95.8% LICOR: Data Continuity: 1 Data recovery: 95.8% LICOR: Data Quality: 1 Temp: 3/827983 out of range [-60 to 30 m/s] Pres: 16/827983 out of range [900 to 1100 mb] DMS: RAID Status from dmesg 3w-9xxx: scsi0: AEN: WARNING (0x04:0x0006): Incomplete unit detected:unit=0. 3w-9xxx: scsi0: AEN: WARNING (0x04:0x0006): Incomplete unit detected:unit=1. 3w-9xxx: scsi0: Found a 3ware 9000 Storage Controller at 0xfb200000, IRQ: 201. 3w-9xxx: scsi0: Firmware FE9X 2.04.00.005, BIOS BE9X 2.03.01.047, Ports: 12. 3w-9xxx: scsi0: AEN: WARNING (0x04:0x0042): Error during read of primary DCB:port=5, error=0x204. ---------------------------------------------------------