eurqclog.20080927.000000.txt Data Quality Summary for Eureka SEARCH Research Station Summary created: Sun Sep 28 01:59:41 2008 Value Interpretation -1: No assessment preformed. 0: All values out of range. 1: Some values in and out of range. 2: All data present and all values in range. ----------------------------------------------------------- STATUS FLAGS ----------------------------------------------------------- MMCR: Millimeter Cloud Radar Instrument Status: 1 Data Continuity: 1 Data Quality: -1 MWR: Microwave Radiometer Instrument Status: 1 Data Continuity: 2 Data Quality: 1 AHSRL: Arctic High Spectral Resolution Lidar Instrument Status: -1 Data Continuity: 1 Data Quality: -1 PAERI: Polar Atmos. Emitted Radiance Interferometer Instrument Status: -1 Data Continuity: -1 Data Quality: -1 SON0: Sonic Anemometer #0 Instrument Status: -1 Data Continuity: 1 Data Quality: 1 SON1: Sonic Anemometer #1 Instrument Status: -1 Data Continuity: 1 Data Quality: 2 LICOR: Licor Measurements Instrument Status: -1 Data Continuity: 1 Data Quality: 1 TOWERMET: Flux Tower Meteorological Measurements Instrument Status: -1 Data Continuity: -1 Data Quality: -1 DMS: Data Management System Filesystem Size Used Avail Use% Mounted on /dev/sda1 2.2T 1.6T 539G 75% /data /dev/sdb1 230G 93M 218G 1% /media/usbdisk /dev/sdc1 230G 175G 44G 80% /media/usbdisk1 ------------------------------------------------------------ --------------- ERROR SUMMARIES --------------- MMCR: Instrument Status: 1 20082710900Health.txt: UPSInputVoltage : 1/120 out of range (108.00 to 126.00), Mean: 117.38, StdDev: 10.91 20082710900Health.txt: UPSOutputVoltage: 1/120 out of range (114.00 to 126.00), Mean: 116.71, StdDev: 10.85 20082711000Health.txt: UPSOutputVoltage: 1/120 out of range (114.00 to 126.00), Mean: 116.61, StdDev: 10.84 20082711000Health.txt: UPSOutputCurrent: 1/120 out of range ( 0.00 to 10.00), Mean: 6.02, StdDev: 0.67 MMCR: Data Continuity: 1 Data recovery: 95.8% MWR: Instrument Status: 1 23.835 CAL: 1/85 out of range, [Tnd +/- 3K] 26.235 CAL: 3/85 out of range, [Tnd +/- 3K] 30.000 CAL: 1/85 out of range, [Tnd +/- 3K] MWR: Data Continuity: 2 Data recovery: 99.9% MWR: Data Quality: 1 TB_30.000: 370/5683 out of range [0-300 K] AHSRL: Data Continuity: 1 Data recovery: 95.8% SONIC0: Data Continuity: 1 Data recovery: 92.1% SONIC0: Data Quality: 1 V: 33042/795851 out of range [-40 to 40 m/s] W: 13/795851 out of range [-20 to 20 m/s] Tv: 33055/795851 out of range [-60 to 30 m/s] SONIC1: Data Continuity: 1 Data recovery: 95.7% LICOR: Data Continuity: 1 Data recovery: 74.7% LICOR: Data Quality: 1 CO2: 20/806906 out of range [0 to 1000 m/s] H2O: 35/806906 out of range [0 to 1000 m/s] Temp: 84/806906 out of range [-60 to 30 m/s] Pres: 243/806906 out of range [900 to 1100 mb] DMS: RAID Status from dmesg 3w-9xxx: scsi0: AEN: WARNING (0x04:0x0006): Incomplete unit detected:unit=1. 3w-9xxx: scsi0: Found a 3ware 9000 Storage Controller at 0xfb200000, IRQ: 201. 3w-9xxx: scsi0: Firmware FE9X 2.04.00.005, BIOS BE9X 2.03.01.047, Ports: 12. 3w-9xxx: scsi0: WARNING: (0x06:0x002C): Unit #0: Command (0x12) timed out, resetting card. 3w-9xxx: scsi0: AEN: WARNING (0x04:0x0042): Error during read of primary DCB:port=2, error=0x204. 3w-9xxx: scsi0: AEN: INFO (0x04:0x005E): Cache synchronized after power fail:unit=0. ---------------------------------------------------------