eurqclog.20090215.000000.txt Data Quality Summary for Eureka SEARCH Research Station Summary created: Mon Feb 16 01:57:15 2009 Value Interpretation -1: No assessment preformed. 0: All values out of range. 1: Some values in and out of range. 2: All data present and all values in range. ----------------------------------------------------------- STATUS FLAGS ----------------------------------------------------------- MMCR: Millimeter Cloud Radar Instrument Status: 1 Data Continuity: 1 Data Quality: -1 MWR: Microwave Radiometer Instrument Status: -1 Data Continuity: 2 Data Quality: 1 AHSRL: Arctic High Spectral Resolution Lidar Instrument Status: -1 Data Continuity: 1 Data Quality: -1 PAERI: Polar Atmos. Emitted Radiance Interferometer Instrument Status: -1 Data Continuity: -1 Data Quality: -1 SON0: Sonic Anemometer #0 Instrument Status: -1 Data Continuity: 2 Data Quality: 1 SON1: Sonic Anemometer #1 Instrument Status: -1 Data Continuity: 2 Data Quality: 1 LICOR: Licor Measurements Instrument Status: -1 Data Continuity: 1 Data Quality: 1 TOWERMET: Flux Tower Meteorological Measurements Instrument Status: -1 Data Continuity: -1 Data Quality: -1 DMS: Data Management System Filesystem Size Used Avail Use% Mounted on /dev/sda1 2.2T 1.6T 472G 78% /data /dev/sdb1 230G 731M 217G 1% /media/usbdisk /dev/sdc1 230G 143G 76G 66% /media/usbdisk1 ------------------------------------------------------------ --------------- ERROR SUMMARIES --------------- MMCR: Instrument Status: 1 20090460200Health.txt: UPSOutputVoltage: 1/120 out of range (114.00 to 126.00), Mean: 117.56, StdDev: 10.93 20090462000Health.txt: UPSInputVoltage : 1/124 out of range (108.00 to 126.00), Mean: 117.85, StdDev: 10.77 20090462000Health.txt: UPSOutputVoltage: 1/124 out of range (114.00 to 126.00), Mean: 117.74, StdDev: 10.76 20090462000Health.txt: UPSOutputCurrent: 1/124 out of range ( 0.00 to 10.00), Mean: 6.08, StdDev: 0.67 MMCR: Data Continuity: 1 Data recovery: 95.8% MWR: Data Continuity: 2 Data recovery: 99.9% MWR: Data Quality: 1 TB_30.000: 194/5683 out of range [0-300 K] AHSRL: Data Continuity: 1 Data recovery: 92.2% SONIC0: Data Continuity: 2 Data recovery: 100.0% SONIC0: Data Quality: 1 U: 846747/863875 out of range [-40 to 40 m/s] V: 863875/863875 out of range [-40 to 40 m/s] W: 345900/863875 out of range [-20 to 20 m/s] Tv: 863875/863875 out of range [-60 to 30 m/s] SONIC1: Data Continuity: 2 Data recovery: 100.0% SONIC1: Data Quality: 1 V: 233/863892 out of range [-40 to 40 m/s] W: 29117/863892 out of range [-20 to 20 m/s] Tv: 863892/863892 out of range [-60 to 30 m/s] LICOR: Data Continuity: 1 Data recovery: 95.8% LICOR: Data Quality: 1 H2O: 497732/827983 out of range [0 to 1000 m/s] Pres: 730965/827983 out of range [900 to 1100 mb] DMS: RAID Status from dmesg 3w-9xxx: scsi0: AEN: WARNING (0x04:0x0008): Unclean shutdown detected:unit=0. 3w-9xxx: scsi0: AEN: WARNING (0x04:0x0006): Incomplete unit detected:unit=3. 3w-9xxx: scsi0: Found a 3ware 9000 Storage Controller at 0xfb200000, IRQ: 201. 3w-9xxx: scsi0: Firmware FE9X 2.04.00.005, BIOS BE9X 2.03.01.047, Ports: 12. 3w-9xxx: scsi0: AEN: INFO (0x04:0x0029): Background verify started:unit=0. 3w-9xxx: scsi0: AEN: INFO (0x04:0x003D): Background verify paused:unit=0. 3w-9xxx: scsi0: AEN: INFO (0x04:0x0029): Background verify started:unit=0. 3w-9xxx: scsi0: AEN: INFO (0x04:0x002B): Background verify done:unit=0. ---------------------------------------------------------