eurqclog.20130331.000000.txt Data Quality Summary for Eureka SEARCH Research Station Summary created: Mon Apr 1 08:13:53 2013 Value Interpretation -1: No assessment preformed. 0: All values out of range. 1: Some values in and out of range. 2: All data present and all values in range. ----------------------------------------------------------- STATUS FLAGS ----------------------------------------------------------- MMCR: Millimeter Cloud Radar Instrument Status: 1 Data Continuity: 1 Data Quality: -1 MWR: Microwave Radiometer Instrument Status: -1 Data Continuity: 2 Data Quality: 1 AHSRL: Arctic High Spectral Resolution Lidar Instrument Status: -1 Data Continuity: -1 Data Quality: -1 PAERI: Polar Atmos. Emitted Radiance Interferometer Instrument Status: -1 Data Continuity: -1 Data Quality: -1 SON0: Sonic Anemometer #0 Instrument Status: -1 Data Continuity: 2 Data Quality: 1 SON1: Sonic Anemometer #1 Instrument Status: -1 Data Continuity: 2 Data Quality: 1 LICOR: Licor Measurements Instrument Status: -1 Data Continuity: 1 Data Quality: 1 TOWERMET: Flux Tower Meteorological Measurements Instrument Status: -1 Data Continuity: -1 Data Quality: -1 DMS: Data Management System ------------------------------------------------------------ --------------- ERROR SUMMARIES --------------- MMCR: Instrument Status: 1 20130900700Health.txt: UPSOutputVoltage: 1/120 out of range (114.00 to 126.00), Mean: 116.35, StdDev: 10.82 20130901400Health.txt: UPSInputVoltage : 2/120 out of range (108.00 to 126.00), Mean: 116.75, StdDev: 15.41 20130901500Health.txt: UPSBatteryVoltage: 1/120 out of range ( 24.00 to 58.00), Mean: 52.85, StdDev: 4.96 20130902000Health.txt: UPSOutputCurrent: 1/120 out of range ( 0.00 to 10.00), Mean: 5.25, StdDev: 0.61 20130902000Health.txt: UPSBatteryVoltage: 1/120 out of range ( 24.00 to 58.00), Mean: 52.85, StdDev: 4.96 MMCR: Data Continuity: 1 Data recovery: 95.8% MWR: Data Continuity: 2 Data recovery: 99.9% MWR: Data Quality: 1 TB_30.000: 5480/5683 out of range [0-300 K] SONIC0: Data Continuity: 2 Data recovery: 100.0% SONIC0: Data Quality: 1 U: 68585/863864 out of range [-40 to 40 m/s] V: 209220/863864 out of range [-40 to 40 m/s] W: 205215/863864 out of range [-20 to 20 m/s] Tv: 194757/863864 out of range [-60 to 30 m/s] SONIC1: Data Continuity: 2 Data recovery: 100.0% SONIC1: Data Quality: 1 U: 252783/863689 out of range [-40 to 40 m/s] V: 200392/863689 out of range [-40 to 40 m/s] W: 71083/863689 out of range [-20 to 20 m/s] Tv: 62581/863689 out of range [-60 to 30 m/s] LICOR: Data Continuity: 1 Data recovery: 95.8% LICOR: Data Quality: 1 H2O: 439309/827982 out of range [0 to 1000 m/s] Temp: 106875/827982 out of range [-60 to 30 m/s] Pres: 681035/827982 out of range [900 to 1100 mb] ---------------------------------------------------------