eurqclog.20130401.000000.txt Data Quality Summary for Eureka SEARCH Research Station Summary created: Tue Apr 2 08:12:34 2013 Value Interpretation -1: No assessment preformed. 0: All values out of range. 1: Some values in and out of range. 2: All data present and all values in range. ----------------------------------------------------------- STATUS FLAGS ----------------------------------------------------------- MMCR: Millimeter Cloud Radar Instrument Status: 1 Data Continuity: 1 Data Quality: -1 MWR: Microwave Radiometer Instrument Status: -1 Data Continuity: 2 Data Quality: 1 AHSRL: Arctic High Spectral Resolution Lidar Instrument Status: -1 Data Continuity: -1 Data Quality: -1 PAERI: Polar Atmos. Emitted Radiance Interferometer Instrument Status: -1 Data Continuity: -1 Data Quality: -1 SON0: Sonic Anemometer #0 Instrument Status: -1 Data Continuity: 1 Data Quality: 1 SON1: Sonic Anemometer #1 Instrument Status: -1 Data Continuity: 2 Data Quality: 1 LICOR: Licor Measurements Instrument Status: -1 Data Continuity: 2 Data Quality: 1 TOWERMET: Flux Tower Meteorological Measurements Instrument Status: -1 Data Continuity: -1 Data Quality: -1 DMS: Data Management System ------------------------------------------------------------ --------------- ERROR SUMMARIES --------------- MMCR: Instrument Status: 1 20130910200Health.txt: UPSInputVoltage : 1/120 out of range (108.00 to 126.00), Mean: 117.41, StdDev: 10.91 20130910200Health.txt: UPSOutputVoltage: 1/120 out of range (114.00 to 126.00), Mean: 116.59, StdDev: 10.85 20130910200Health.txt: UPSOutputCurrent: 1/120 out of range ( 0.00 to 10.00), Mean: 5.38, StdDev: 0.66 20130910200Health.txt: UPSBatteryVoltage: 1/120 out of range ( 24.00 to 58.00), Mean: 52.85, StdDev: 4.96 20130910700Health.txt: UPSInputVoltage : 1/120 out of range (108.00 to 126.00), Mean: 117.02, StdDev: 10.87 20130910700Health.txt: UPSOutputCurrent: 1/120 out of range ( 0.00 to 10.00), Mean: 5.27, StdDev: 0.60 20130910900Health.txt: UPSBatteryVoltage: 1/120 out of range ( 24.00 to 58.00), Mean: 52.85, StdDev: 4.96 20130911400Health.txt: UPSBatteryVoltage: 1/120 out of range ( 24.00 to 58.00), Mean: 52.85, StdDev: 4.96 20130911600Health.txt: UPSInputVoltage : 1/120 out of range (108.00 to 126.00), Mean: 117.14, StdDev: 10.89 20130911600Health.txt: UPSOutputVoltage: 1/120 out of range (114.00 to 126.00), Mean: 116.53, StdDev: 10.83 20130911600Health.txt: UPSOutputCurrent: 1/120 out of range ( 0.00 to 10.00), Mean: 5.34, StdDev: 0.62 20130911600Health.txt: UPSBatteryVoltage: 1/120 out of range ( 24.00 to 58.00), Mean: 52.85, StdDev: 4.96 20130912000Health.txt: UPSOutputVoltage: 1/120 out of range (114.00 to 126.00), Mean: 116.90, StdDev: 10.89 20130912000Health.txt: UPSOutputCurrent: 1/120 out of range ( 0.00 to 10.00), Mean: 5.51, StdDev: 0.71 MMCR: Data Continuity: 1 Data recovery: 95.8% MWR: Data Continuity: 2 Data recovery: 99.9% MWR: Data Quality: 1 TB_30.000: 5500/5683 out of range [0-300 K] SONIC0: Data Continuity: 1 Data recovery: 95.8% SONIC0: Data Quality: 1 V: 263591/827918 out of range [-40 to 40 m/s] W: 157187/827918 out of range [-20 to 20 m/s] Tv: 148912/827918 out of range [-60 to 30 m/s] SONIC1: Data Continuity: 2 Data recovery: 100.0% SONIC1: Data Quality: 1 U: 370361/863892 out of range [-40 to 40 m/s] V: 1747/863892 out of range [-40 to 40 m/s] W: 2322/863892 out of range [-20 to 20 m/s] Tv: 2088/863892 out of range [-60 to 30 m/s] LICOR: Data Continuity: 2 Data recovery: 100.0% LICOR: Data Quality: 1 H2O: 357407/863921 out of range [0 to 1000 m/s] Temp: 3/863921 out of range [-60 to 30 m/s] Pres: 746778/863921 out of range [900 to 1100 mb] ---------------------------------------------------------