eurqclog.20131101.000000.txt Data Quality Summary for Eureka SEARCH Research Station Summary created: Sat Nov 2 08:13:11 2013 Value Interpretation -1: No assessment preformed. 0: All values out of range. 1: Some values in and out of range. 2: All data present and all values in range. ----------------------------------------------------------- STATUS FLAGS ----------------------------------------------------------- MMCR: Millimeter Cloud Radar Instrument Status: 1 Data Continuity: -1 Data Quality: -1 MWR: Microwave Radiometer Instrument Status: 1 Data Continuity: 2 Data Quality: 1 AHSRL: Arctic High Spectral Resolution Lidar Instrument Status: -1 Data Continuity: -1 Data Quality: -1 PAERI: Polar Atmos. Emitted Radiance Interferometer Instrument Status: -1 Data Continuity: -1 Data Quality: -1 SON0: Sonic Anemometer #0 Instrument Status: -1 Data Continuity: 1 Data Quality: 1 SON1: Sonic Anemometer #1 Instrument Status: -1 Data Continuity: 1 Data Quality: 1 LICOR: Licor Measurements Instrument Status: -1 Data Continuity: 1 Data Quality: 1 TOWERMET: Flux Tower Meteorological Measurements Instrument Status: -1 Data Continuity: -1 Data Quality: -1 DMS: Data Management System ------------------------------------------------------------ --------------- ERROR SUMMARIES --------------- MMCR: Instrument Status: 1 20133050200Health.txt: temperature (outdoor): 1/0 out of range ( 3.00 to 0.00), Mean: ******, StdDev: 9.00 20133050200Health.txt: UPSBatteryVoltage: 1/93 out of range ( 24.00 to 58.00), Mean: 52.72, StdDev: 5.63 20133050300Health.txt: temperature (outdoor): 1/0 out of range ( 3.00 to 0.00), Mean: ******, StdDev: 9.00 20133050300Health.txt: UPSBatteryVoltage: 1/93 out of range ( 24.00 to 58.00), Mean: 52.72, StdDev: 5.63 20133050400Health.txt: temperature (outdoor): 1/0 out of range ( 3.00 to 0.00), Mean: ******, StdDev: 9.00 20133050400Health.txt: UPSBatteryVoltage: 1/93 out of range ( 24.00 to 58.00), Mean: 52.72, StdDev: 5.63 20133050700Health.txt: UPSInputVoltage : 1/187 out of range (108.00 to 126.00), Mean: 116.96, StdDev: 8.69 20133050700Health.txt: UPSOutputVoltage: 1/187 out of range (114.00 to 126.00), Mean: 116.96, StdDev: 8.69 20133050700Health.txt: UPSOutputCurrent: 1/187 out of range ( 0.00 to 10.00), Mean: 5.36, StdDev: 0.50 20133050800Health.txt: UPSInputVoltage : 1/187 out of range (108.00 to 126.00), Mean: 116.96, StdDev: 8.69 20133050800Health.txt: UPSOutputVoltage: 1/187 out of range (114.00 to 126.00), Mean: 116.96, StdDev: 8.69 20133050800Health.txt: UPSOutputCurrent: 1/187 out of range ( 0.00 to 10.00), Mean: 5.36, StdDev: 0.50 20133050900Health.txt: UPSBatteryVoltage: 1/184 out of range ( 24.00 to 58.00), Mean: 53.00, StdDev: 4.00 20133051400Health.txt: UPSInputVoltage : 1/93 out of range (108.00 to 126.00), Mean: 115.86, StdDev: 12.26 20133051400Health.txt: UPSOutputVoltage: 1/93 out of range (114.00 to 126.00), Mean: 116.28, StdDev: 12.31 20133051400Health.txt: UPSOutputCurrent: 1/93 out of range ( 0.00 to 10.00), Mean: 5.32, StdDev: 0.69 20133051400Health.txt: UPSBatteryVoltage: 1/93 out of range ( 24.00 to 58.00), Mean: 52.72, StdDev: 5.63 20133052000Health.txt: UPSInputVoltage : 1/187 out of range (108.00 to 126.00), Mean: 116.88, StdDev: 8.68 20133052000Health.txt: UPSOutputVoltage: 1/187 out of range (114.00 to 126.00), Mean: 116.97, StdDev: 8.69 20133052000Health.txt: UPSOutputCurrent: 1/187 out of range ( 0.00 to 10.00), Mean: 5.33, StdDev: 0.51 MWR: Instrument Status: 1 30.000 CAL: 2/2 out of range, [Tnd +/- 3K] MWR: Data Continuity: 2 Data recovery: 99.9% MWR: Data Quality: 1 TB_30.000: 5595/5683 out of range [0-300 K] SONIC0: Data Continuity: 1 Data recovery: 9.9% SONIC0: Data Quality: 1 U: 8/83468 out of range [-40 to 40 m/s] V: 28873/83468 out of range [-40 to 40 m/s] W: 83468/83468 out of range [-20 to 20 m/s] Tv: 83468/83468 out of range [-60 to 30 m/s] SONIC1: Data Continuity: 1 Data recovery: 9.1% SONIC1: Data Quality: 1 U: 64268/64268 out of range [-40 to 40 m/s] V: 6355/64268 out of range [-40 to 40 m/s] W: 63061/64268 out of range [-20 to 20 m/s] Tv: 62230/64268 out of range [-60 to 30 m/s] LICOR: Data Continuity: 1 Data recovery: 10.0% LICOR: Data Quality: 1 H2O: 86758/86759 out of range [0 to 1000 m/s] Pres: 86759/86759 out of range [900 to 1100 mb] ---------------------------------------------------------