eurqclog.20140110.000000.txt Data Quality Summary for Eureka SEARCH Research Station Summary created: Sat Jan 11 08:14:20 2014 Value Interpretation -1: No assessment preformed. 0: All values out of range. 1: Some values in and out of range. 2: All data present and all values in range. ----------------------------------------------------------- STATUS FLAGS ----------------------------------------------------------- MMCR: Millimeter Cloud Radar Instrument Status: 1 Data Continuity: 2 Data Quality: -1 MWR: Microwave Radiometer Instrument Status: 1 Data Continuity: 2 Data Quality: 1 AHSRL: Arctic High Spectral Resolution Lidar Instrument Status: -1 Data Continuity: -1 Data Quality: -1 PAERI: Polar Atmos. Emitted Radiance Interferometer Instrument Status: -1 Data Continuity: -1 Data Quality: -1 SON0: Sonic Anemometer #0 Instrument Status: -1 Data Continuity: 1 Data Quality: 1 SON1: Sonic Anemometer #1 Instrument Status: -1 Data Continuity: 2 Data Quality: 1 LICOR: Licor Measurements Instrument Status: -1 Data Continuity: 2 Data Quality: 1 TOWERMET: Flux Tower Meteorological Measurements Instrument Status: -1 Data Continuity: -1 Data Quality: -1 DMS: Data Management System ------------------------------------------------------------ --------------- ERROR SUMMARIES --------------- MMCR: Instrument Status: 1 20140100100Health.txt: UPSInputVoltage : 1/120 out of range (108.00 to 126.00), Mean: 116.43, StdDev: 10.82 20140100100Health.txt: UPSOutputVoltage: 1/120 out of range (114.00 to 126.00), Mean: 117.58, StdDev: 10.93 20140100100Health.txt: UPSOutputCurrent: 1/120 out of range ( 0.00 to 10.00), Mean: 6.29, StdDev: 0.69 20140100100Health.txt: UPSBatteryVoltage: 1/120 out of range ( 24.00 to 58.00), Mean: 52.85, StdDev: 4.96 20140100200Health.txt: UPSOutputCurrent: 1/120 out of range ( 0.00 to 10.00), Mean: 6.30, StdDev: 0.69 20140100600Health.txt: 2GHzPhaseLock 0=TTL lo: 6/10 out of range ( 0.90 to 1.10), Mean: 0.40, StdDev: 0.52 20140100700Health.txt: 2GHzPhaseLock 0=TTL lo: 8/10 out of range ( 0.90 to 1.10), Mean: 0.20, StdDev: 0.42 20140100800Health.txt: UPSOutputVoltage: 1/120 out of range (114.00 to 126.00), Mean: 117.58, StdDev: 10.93 20140100800Health.txt: UPSOutputCurrent: 1/120 out of range ( 0.00 to 10.00), Mean: 6.28, StdDev: 0.69 20140101900Health.txt: UPSOutputVoltage: 1/120 out of range (114.00 to 126.00), Mean: 117.48, StdDev: 10.92 20140102000Health.txt: UPSInputVoltage : 1/120 out of range (108.00 to 126.00), Mean: 116.48, StdDev: 10.83 20140102000Health.txt: UPSOutputVoltage: 1/120 out of range (114.00 to 126.00), Mean: 117.60, StdDev: 10.93 20140102000Health.txt: UPSOutputCurrent: 1/120 out of range ( 0.00 to 10.00), Mean: 6.30, StdDev: 0.69 20140102000Health.txt: UPSBatteryVoltage: 1/120 out of range ( 24.00 to 58.00), Mean: 52.85, StdDev: 4.96 MMCR: Data Continuity: 2 Data recovery: 100.0% MWR: Instrument Status: 1 30.000 CAL: 10/10 out of range, [Tnd +/- 3K] MWR: Data Continuity: 2 Data recovery: 99.9% MWR: Data Quality: 1 TB_30.000: 5629/5683 out of range [0-300 K] SONIC0: Data Continuity: 1 Data recovery: 95.8% SONIC0: Data Quality: 1 U: 814328/827296 out of range [-40 to 40 m/s] V: 789811/827296 out of range [-40 to 40 m/s] W: 781655/827296 out of range [-20 to 20 m/s] Tv: 826145/827296 out of range [-60 to 30 m/s] SONIC1: Data Continuity: 2 Data recovery: 100.0% SONIC1: Data Quality: 1 U: 527056/862405 out of range [-40 to 40 m/s] V: 817444/862405 out of range [-40 to 40 m/s] W: 861335/862405 out of range [-20 to 20 m/s] Tv: 862397/862405 out of range [-60 to 30 m/s] LICOR: Data Continuity: 2 Data recovery: 100.0% LICOR: Data Quality: 1 CO2: 10474/863921 out of range [0 to 1000 m/s] H2O: 631466/863921 out of range [0 to 1000 m/s] Temp: 9645/863921 out of range [-60 to 30 m/s] Pres: 579596/863921 out of range [900 to 1100 mb] ---------------------------------------------------------