eurqclog.20140405.000000.txt Data Quality Summary for Eureka SEARCH Research Station Summary created: Sun Apr 6 08:11:24 2014 Value Interpretation -1: No assessment preformed. 0: All values out of range. 1: Some values in and out of range. 2: All data present and all values in range. ----------------------------------------------------------- STATUS FLAGS ----------------------------------------------------------- MMCR: Millimeter Cloud Radar Instrument Status: 1 Data Continuity: 1 Data Quality: -1 MWR: Microwave Radiometer Instrument Status: 1 Data Continuity: 2 Data Quality: 1 AHSRL: Arctic High Spectral Resolution Lidar Instrument Status: -1 Data Continuity: -1 Data Quality: -1 PAERI: Polar Atmos. Emitted Radiance Interferometer Instrument Status: -1 Data Continuity: -1 Data Quality: -1 SON0: Sonic Anemometer #0 Instrument Status: -1 Data Continuity: 2 Data Quality: 1 SON1: Sonic Anemometer #1 Instrument Status: -1 Data Continuity: 2 Data Quality: 1 LICOR: Licor Measurements Instrument Status: -1 Data Continuity: 1 Data Quality: 1 TOWERMET: Flux Tower Meteorological Measurements Instrument Status: -1 Data Continuity: -1 Data Quality: -1 DMS: Data Management System ------------------------------------------------------------ --------------- ERROR SUMMARIES --------------- MMCR: Instrument Status: 1 20140950200Health.txt: UPSBatteryVoltage: 49/120 out of range ( 24.00 to 58.00), Mean: 55.72, StdDev: 2.46 20140950300Health.txt: temperature (outdoor): 1/2 out of range ( 0.00 to 0.00), Mean: ******, StdDev: 1.00 20140951300Health.txt: UPSInputVoltage : 1/120 out of range (108.00 to 126.00), Mean: 116.36, StdDev: 10.82 20140951300Health.txt: UPSOutputVoltage: 1/120 out of range (114.00 to 126.00), Mean: 117.51, StdDev: 10.92 20140951300Health.txt: UPSOutputCurrent: 1/120 out of range ( 0.00 to 10.00), Mean: 5.69, StdDev: 0.63 20140951300Health.txt: UPSBatteryVoltage: 1/120 out of range ( 24.00 to 58.00), Mean: 52.85, StdDev: 4.96 20140951400Health.txt: UPSInputVoltage : 2/120 out of range (108.00 to 126.00), Mean: 115.26, StdDev: 15.21 20140951400Health.txt: UPSOutputVoltage: 2/120 out of range (114.00 to 126.00), Mean: 116.44, StdDev: 15.36 20140951400Health.txt: UPSOutputCurrent: 2/120 out of range ( 0.00 to 10.00), Mean: 5.61, StdDev: 0.87 20140951400Health.txt: UPSBatteryVoltage: 3/120 out of range ( 24.00 to 58.00), Mean: 51.94, StdDev: 8.51 20140952000Health.txt: UPSOutputCurrent: 1/120 out of range ( 0.00 to 10.00), Mean: 5.72, StdDev: 0.64 MMCR: Data Continuity: 1 Data recovery: 50.0% MWR: Instrument Status: 1 30.000 CAL: 22/22 out of range, [Tnd +/- 3K] MWR: Data Continuity: 2 Data recovery: 99.9% MWR: Data Quality: 1 TB_30.000: 5667/5683 out of range [0-300 K] SONIC0: Data Continuity: 2 Data recovery: 100.0% SONIC0: Data Quality: 1 U: 85555/863855 out of range [-40 to 40 m/s] V: 244592/863855 out of range [-40 to 40 m/s] W: 279892/863855 out of range [-20 to 20 m/s] Tv: 269280/863855 out of range [-60 to 30 m/s] SONIC1: Data Continuity: 2 Data recovery: 100.0% SONIC1: Data Quality: 1 U: 348429/860621 out of range [-40 to 40 m/s] V: 248913/860621 out of range [-40 to 40 m/s] W: 303239/860621 out of range [-20 to 20 m/s] Tv: 280287/860621 out of range [-60 to 30 m/s] LICOR: Data Continuity: 1 Data recovery: 95.8% LICOR: Data Quality: 1 H2O: 692592/827982 out of range [0 to 1000 m/s] Temp: 460548/827982 out of range [-60 to 30 m/s] Pres: 778539/827982 out of range [900 to 1100 mb] ---------------------------------------------------------