eurqclog.20060409.000000.txt Data Quality Summary for Eureka SEARCH Research Station Summary created: Mon Apr 10 00:52:38 2006 Value Interpretation -1: No assessment preformed. 0: All values out of range. 1: Some values in and out of range. 2: All data present and all values in range. ----------------------------------------------------------- STATUS FLAGS ----------------------------------------------------------- MMCR: Millimeter Cloud Radar Instrument Status: 1 Data Continuity: 2 Data Quality: -1 MWR: Microwave Radiometer Instrument Status: -1 Data Continuity: -1 Data Quality: -1 AHSRL: Arctic High Spectral Resolution Lidar Instrument Status: -1 Data Continuity: 2 Data Quality: -1 DMS: Data Management System Filesystem Size Used Avail Use% Mounted on /dev/sda1 2.2T 1.4T 746G 65% /data /dev/sdc1 230G 93M 218G 1% /media/usbdisk /dev/sdb1 230G 56G 162G 26% /media/usbdisk1 ------------------------------------------------------------ --------------- ERROR SUMMARIES --------------- MMCR: Instrument Status: 1 20060990100Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.24, StdDev: 0.31 20060990200Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.34, StdDev: 0.26 20060990300Health.txt: humidity (indoor): 28/28 out of range ( 10.00 to 75.00), Mean: -0.31, StdDev: 0.33 20060990400Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.34, StdDev: 0.26 20060990500Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.22, StdDev: 0.40 20060990600Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.34, StdDev: 0.37 20060990700Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.29, StdDev: 0.36 20060990800Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.17, StdDev: 0.24 20060990900Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.34, StdDev: 0.35 20060991000Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.30, StdDev: 0.30 20060991100Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.29, StdDev: 0.28 20060991200Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.20, StdDev: 0.33 20060991300Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.22, StdDev: 0.28 20060991400Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.32, StdDev: 0.27 20060991500Health.txt: humidity (indoor): 28/28 out of range ( 10.00 to 75.00), Mean: -0.26, StdDev: 0.34 20060991600Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.25, StdDev: 0.25 20060991700Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.25, StdDev: 0.34 20060991800Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.20, StdDev: 0.31 20060991900Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.39, StdDev: 0.40 20060992000Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.22, StdDev: 0.25 20060992100Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.20, StdDev: 0.31 20060992200Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.17, StdDev: 0.35 20060992300Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.19, StdDev: 0.24 DMS: RAID Status from dmesg 3w-9xxx: scsi0: Found a 3ware 9000 Storage Controller at 0xfb200000, IRQ: 201. 3w-9xxx: scsi0: Firmware FE9X 2.04.00.005, BIOS BE9X 2.03.01.047, Ports: 12. 3w-9xxx: scsi0: ERROR: (0x03:0x0104): SGL entry has illegal length:address=0x3713E000, length=0xFF, cmd=X. 3w-9xxx: scsi0: ERROR: (0x03:0x0104): SGL entry has illegal length:address=0x36368000, length=0xFF, cmd=X. 3w-9xxx: scsi0: AEN: ERROR (0x04:0x0002): Degraded unit detected:unit=0, port=2. 3w-9xxx: scsi0: AEN: INFO (0x04:0x000B): Rebuild started:unit=0. 3w-9xxx: scsi0: AEN: INFO (0x04:0x003B): Background rebuild paused:unit=0. 3w-9xxx: scsi0: AEN: INFO (0x04:0x000B): Rebuild started:unit=0. 3w-9xxx: scsi0: AEN: INFO (0x04:0x0005): Background rebuild done:unit=0. 3w-9xxx: scsi0: AEN: ERROR (0x04:0x0002): Degraded unit detected:unit=0, port=2. 3w-9xxx: scsi0: AEN: INFO (0x04:0x000B): Rebuild started:unit=0. 3w-9xxx: scsi0: AEN: INFO (0x04:0x0005): Background rebuild done:unit=0. ---------------------------------------------------------