eurqclog.20060415.000000.txt Data Quality Summary for Eureka SEARCH Research Station Summary created: Sun Apr 16 01:22:43 2006 Value Interpretation -1: No assessment preformed. 0: All values out of range. 1: Some values in and out of range. 2: All data present and all values in range. ----------------------------------------------------------- STATUS FLAGS ----------------------------------------------------------- MMCR: Millimeter Cloud Radar Instrument Status: 1 Data Continuity: 2 Data Quality: -1 MWR: Microwave Radiometer Instrument Status: -1 Data Continuity: -1 Data Quality: -1 AHSRL: Arctic High Spectral Resolution Lidar Instrument Status: -1 Data Continuity: 1 Data Quality: -1 DMS: Data Management System Filesystem Size Used Avail Use% Mounted on /dev/sda1 2.2T 1.4T 705G 67% /data /dev/sdc1 230G 93M 218G 1% /media/usbdisk /dev/sdb1 230G 97G 122G 45% /media/usbdisk1 ------------------------------------------------------------ --------------- ERROR SUMMARIES --------------- MMCR: Instrument Status: 1 20061050100Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.20, StdDev: 0.31 20061050200Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.34, StdDev: 0.29 20061050300Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.22, StdDev: 0.33 20061050400Health.txt: humidity (indoor): 28/28 out of range ( 10.00 to 75.00), Mean: -0.21, StdDev: 0.31 20061050500Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.24, StdDev: 0.28 20061050600Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.20, StdDev: 0.31 20061050700Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.30, StdDev: 0.42 20061050800Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.34, StdDev: 0.29 20061050900Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.30, StdDev: 0.27 20061051000Health.txt: humidity (indoor): 28/28 out of range ( 10.00 to 75.00), Mean: -0.21, StdDev: 0.31 20061051100Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.27, StdDev: 0.28 20061051200Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.29, StdDev: 0.28 20061051300Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.27, StdDev: 0.28 20061051400Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.29, StdDev: 0.33 20061051500Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.24, StdDev: 0.25 20061051600Health.txt: humidity (indoor): 28/28 out of range ( 10.00 to 75.00), Mean: -0.30, StdDev: 0.28 20061051700Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.30, StdDev: 0.30 20061051800Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.27, StdDev: 0.36 20061051900Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.24, StdDev: 0.34 20061052000Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.19, StdDev: 0.30 20061052100Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.27, StdDev: 0.33 20061052200Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.25, StdDev: 0.31 20061052300Health.txt: humidity (indoor): 29/29 out of range ( 10.00 to 75.00), Mean: -0.25, StdDev: 0.31 AHSRL: Data Continuity: 1 Data recovery: 94.7% DMS: RAID Status from dmesg 3w-9xxx: scsi0: Found a 3ware 9000 Storage Controller at 0xfb200000, IRQ: 201. 3w-9xxx: scsi0: Firmware FE9X 2.04.00.005, BIOS BE9X 2.03.01.047, Ports: 12. 3w-9xxx: scsi0: ERROR: (0x03:0x0104): SGL entry has illegal length:address=0x3713E000, length=0xFF, cmd=X. 3w-9xxx: scsi0: ERROR: (0x03:0x0104): SGL entry has illegal length:address=0x36368000, length=0xFF, cmd=X. 3w-9xxx: scsi0: AEN: ERROR (0x04:0x0002): Degraded unit detected:unit=0, port=2. 3w-9xxx: scsi0: AEN: INFO (0x04:0x000B): Rebuild started:unit=0. 3w-9xxx: scsi0: AEN: INFO (0x04:0x003B): Background rebuild paused:unit=0. 3w-9xxx: scsi0: AEN: INFO (0x04:0x000B): Rebuild started:unit=0. 3w-9xxx: scsi0: AEN: INFO (0x04:0x0005): Background rebuild done:unit=0. 3w-9xxx: scsi0: AEN: ERROR (0x04:0x0002): Degraded unit detected:unit=0, port=2. 3w-9xxx: scsi0: AEN: INFO (0x04:0x000B): Rebuild started:unit=0. 3w-9xxx: scsi0: AEN: INFO (0x04:0x0005): Background rebuild done:unit=0. ---------------------------------------------------------