eurqclog.20080510.000000.txt Data Quality Summary for Eureka SEARCH Research Station Summary created: Sun May 11 01:24:28 2008 Value Interpretation -1: No assessment preformed. 0: All values out of range. 1: Some values in and out of range. 2: All data present and all values in range. ----------------------------------------------------------- STATUS FLAGS ----------------------------------------------------------- MMCR: Millimeter Cloud Radar Instrument Status: 1 Data Continuity: 1 Data Quality: -1 MWR: Microwave Radiometer Instrument Status: 2 Data Continuity: 2 Data Quality: 1 AHSRL: Arctic High Spectral Resolution Lidar Instrument Status: -1 Data Continuity: -1 Data Quality: -1 PAERI: Polar Atmos. Emitted Radiance Interferometer Instrument Status: -1 Data Continuity: -1 Data Quality: -1 SON0: Sonic Anemometer #0 Instrument Status: -1 Data Continuity: 2 Data Quality: 2 SON1: Sonic Anemometer #1 Instrument Status: -1 Data Continuity: 1 Data Quality: 2 LICOR: Licor Measurements Instrument Status: -1 Data Continuity: 1 Data Quality: 1 TOWERMET: Flux Tower Meteorological Measurements Instrument Status: -1 Data Continuity: -1 Data Quality: -1 DMS: Data Management System Filesystem Size Used Avail Use% Mounted on /dev/sda1 2.2T 1.7T 395G 82% /data /dev/sdb1 230G 120G 99G 55% /media/usbdisk /dev/sdc1 230G 93M 218G 1% /media/usbdisk1 ------------------------------------------------------------ --------------- ERROR SUMMARIES --------------- MMCR: Instrument Status: 1 20081310300Health.txt: temperature (outdoor): 1/2 out of range ( 0.00 to 0.00), Mean: ******, StdDev: 8.00 20081310400Health.txt: UPSOutputVoltage: 1/120 out of range (114.00 to 126.00), Mean: 117.08, StdDev: 10.89 20081310400Health.txt: UPSOutputCurrent: 1/120 out of range ( 0.00 to 10.00), Mean: 5.86, StdDev: 0.66 20081310500Health.txt: UPSInputVoltage : 1/120 out of range (108.00 to 126.00), Mean: 116.99, StdDev: 10.86 20081310500Health.txt: UPSOutputVoltage: 1/120 out of range (114.00 to 126.00), Mean: 117.28, StdDev: 10.91 20081310500Health.txt: UPSOutputCurrent: 2/120 out of range ( 0.00 to 10.00), Mean: 5.84, StdDev: 0.93 20081310500Health.txt: UPSBatteryVoltage: 1/120 out of range ( 24.00 to 58.00), Mean: 52.85, StdDev: 4.96 20081311000Health.txt: UPSBatteryVoltage: 2/120 out of range ( 24.00 to 58.00), Mean: 52.39, StdDev: 6.98 20081311400Health.txt: UPSInputVoltage : 1/120 out of range (108.00 to 126.00), Mean: 117.00, StdDev: 10.86 20081311400Health.txt: UPSOutputVoltage: 1/120 out of range (114.00 to 126.00), Mean: 117.42, StdDev: 10.92 20081311400Health.txt: UPSOutputCurrent: 1/120 out of range ( 0.00 to 10.00), Mean: 5.84, StdDev: 0.66 20081311400Health.txt: UPSBatteryVoltage: 1/120 out of range ( 24.00 to 58.00), Mean: 52.85, StdDev: 4.96 20081312100Health.txt: 2GHzPhaseLock 0=TTL lo: 1/10 out of range ( 0.90 to 1.10), Mean: 0.90, StdDev: 0.32 20081312200Health.txt: 2GHzPhaseLock 0=TTL lo: 4/10 out of range ( 0.90 to 1.10), Mean: 0.60, StdDev: 0.52 20081312300Health.txt: 2GHzPhaseLock 0=TTL lo: 4/10 out of range ( 0.90 to 1.10), Mean: 0.60, StdDev: 0.52 MMCR: Data Continuity: 1 Data recovery: 95.6% MWR: Data Continuity: 2 Data recovery: 99.9% MWR: Data Quality: 1 TB_30.000: 775/5683 out of range [0-300 K] SONIC0: Data Continuity: 2 Data recovery: 100.0% SONIC1: Data Continuity: 1 Data recovery: 20.9% LICOR: Data Continuity: 1 Data recovery: 64.3% LICOR: Data Quality: 1 CO2: 25/848960 out of range [0 to 1000 m/s] H2O: 65/848960 out of range [0 to 1000 m/s] Temp: 211/848960 out of range [-60 to 30 m/s] Pres: 709/848960 out of range [900 to 1100 mb] DMS: RAID Status from dmesg 3w-9xxx: scsi0: AEN: WARNING (0x04:0x0008): Unclean shutdown detected:unit=0. 3w-9xxx: scsi0: Found a 3ware 9000 Storage Controller at 0xfb200000, IRQ: 201. 3w-9xxx: scsi0: Firmware FE9X 2.04.00.005, BIOS BE9X 2.03.01.047, Ports: 12. 3w-9xxx: scsi0: AEN: INFO (0x04:0x0029): Background verify started:unit=0. 3w-9xxx: scsi0: AEN: INFO (0x04:0x002B): Background verify done:unit=0. ---------------------------------------------------------