eurqclog.20080523.000000.txt Data Quality Summary for Eureka SEARCH Research Station Summary created: Sat May 24 01:25:51 2008 Value Interpretation -1: No assessment preformed. 0: All values out of range. 1: Some values in and out of range. 2: All data present and all values in range. ----------------------------------------------------------- STATUS FLAGS ----------------------------------------------------------- MMCR: Millimeter Cloud Radar Instrument Status: 1 Data Continuity: 1 Data Quality: -1 MWR: Microwave Radiometer Instrument Status: 2 Data Continuity: 1 Data Quality: 1 AHSRL: Arctic High Spectral Resolution Lidar Instrument Status: -1 Data Continuity: -1 Data Quality: -1 PAERI: Polar Atmos. Emitted Radiance Interferometer Instrument Status: -1 Data Continuity: -1 Data Quality: -1 SON0: Sonic Anemometer #0 Instrument Status: -1 Data Continuity: 1 Data Quality: 2 SON1: Sonic Anemometer #1 Instrument Status: -1 Data Continuity: 1 Data Quality: 2 LICOR: Licor Measurements Instrument Status: -1 Data Continuity: 1 Data Quality: 1 TOWERMET: Flux Tower Meteorological Measurements Instrument Status: -1 Data Continuity: -1 Data Quality: -1 DMS: Data Management System Filesystem Size Used Avail Use% Mounted on /dev/sda1 2.2T 1.7T 398G 81% /data /dev/sdb1 230G 137G 82G 63% /media/usbdisk /dev/sdc1 230G 93M 218G 1% /media/usbdisk1 ------------------------------------------------------------ --------------- ERROR SUMMARIES --------------- MMCR: Instrument Status: 1 20081441700Health.txt: UPSInputVoltage : 1/120 out of range (108.00 to 126.00), Mean: 117.10, StdDev: 10.88 20081441700Health.txt: UPSOutputVoltage: 1/120 out of range (114.00 to 126.00), Mean: 117.16, StdDev: 10.89 20081441700Health.txt: UPSOutputCurrent: 1/120 out of range ( 0.00 to 10.00), Mean: 5.62, StdDev: 0.67 20081441700Health.txt: UPSBatteryVoltage: 1/120 out of range ( 24.00 to 58.00), Mean: 52.85, StdDev: 4.96 20081442000Health.txt: UPSInputVoltage : 36/120 out of range (108.00 to 126.00), Mean: 84.43, StdDev: 52.88 20081442200Health.txt: UPSBatteryVoltage: 45/120 out of range ( 24.00 to 58.00), Mean: 57.44, StdDev: 0.96 20081442300Health.txt: UPSBatteryVoltage: 120/120 out of range ( 24.00 to 58.00), Mean: 58.50, StdDev: 0.00 MMCR: Data Continuity: 1 Data recovery: 38.6% MWR: Data Continuity: 1 Data recovery: 79.5% MWR: Data Quality: 1 TB_30.000: 653/4522 out of range [0-300 K] SONIC0: Data Continuity: 1 Data recovery: 79.2% SONIC1: Data Continuity: 1 Data recovery: 81.9% LICOR: Data Continuity: 1 Data recovery: 79.4% LICOR: Data Quality: 1 Temp: 4/686180 out of range [-60 to 30 m/s] Pres: 18/686180 out of range [900 to 1100 mb] DMS: RAID Status from dmesg 3w-9xxx: scsi0: Found a 3ware 9000 Storage Controller at 0xfb200000, IRQ: 201. 3w-9xxx: scsi0: Firmware FE9X 2.04.00.005, BIOS BE9X 2.03.01.047, Ports: 12. ---------------------------------------------------------