eurqclog.20080527.000000.txt Data Quality Summary for Eureka SEARCH Research Station Summary created: Wed May 28 01:41:01 2008 Value Interpretation -1: No assessment preformed. 0: All values out of range. 1: Some values in and out of range. 2: All data present and all values in range. ----------------------------------------------------------- STATUS FLAGS ----------------------------------------------------------- MMCR: Millimeter Cloud Radar Instrument Status: 1 Data Continuity: 1 Data Quality: -1 MWR: Microwave Radiometer Instrument Status: 2 Data Continuity: 2 Data Quality: 1 AHSRL: Arctic High Spectral Resolution Lidar Instrument Status: -1 Data Continuity: 0 Data Quality: -1 PAERI: Polar Atmos. Emitted Radiance Interferometer Instrument Status: -1 Data Continuity: -1 Data Quality: -1 SON0: Sonic Anemometer #0 Instrument Status: -1 Data Continuity: 0 Data Quality: 2 SON1: Sonic Anemometer #1 Instrument Status: -1 Data Continuity: 1 Data Quality: 2 LICOR: Licor Measurements Instrument Status: -1 Data Continuity: 1 Data Quality: 1 TOWERMET: Flux Tower Meteorological Measurements Instrument Status: -1 Data Continuity: -1 Data Quality: -1 DMS: Data Management System Filesystem Size Used Avail Use% Mounted on /dev/sda1 2.2T 1.7T 402G 81% /data /dev/sdb1 230G 138G 80G 64% /media/usbdisk /dev/sdc1 230G 93M 218G 1% /media/usbdisk1 ------------------------------------------------------------ --------------- ERROR SUMMARIES --------------- MMCR: Instrument Status: 1 20081480600Health.txt: UPSInputVoltage : 2/120 out of range (108.00 to 126.00), Mean: 116.76, StdDev: 15.40 20081480600Health.txt: UPSOutputVoltage: 2/120 out of range (114.00 to 126.00), Mean: 116.32, StdDev: 15.36 20081480600Health.txt: UPSOutputCurrent: 2/120 out of range ( 0.00 to 10.00), Mean: 5.83, StdDev: 0.92 20081480600Health.txt: UPSBatteryVoltage: 2/120 out of range ( 24.00 to 58.00), Mean: 52.39, StdDev: 6.98 20081480700Health.txt: UPSInputVoltage : 1/120 out of range (108.00 to 126.00), Mean: 117.78, StdDev: 10.94 20081480700Health.txt: UPSOutputVoltage: 1/120 out of range (114.00 to 126.00), Mean: 117.41, StdDev: 10.92 20081480700Health.txt: UPSOutputCurrent: 1/120 out of range ( 0.00 to 10.00), Mean: 5.84, StdDev: 0.65 20081480700Health.txt: UPSBatteryVoltage: 1/120 out of range ( 24.00 to 58.00), Mean: 52.85, StdDev: 4.96 20081482200Health.txt: UPSInputVoltage : 1/120 out of range (108.00 to 126.00), Mean: 117.68, StdDev: 10.94 20081482200Health.txt: UPSOutputVoltage: 1/120 out of range (114.00 to 126.00), Mean: 117.47, StdDev: 10.92 20081482300Health.txt: UPSBatteryVoltage: 2/120 out of range ( 24.00 to 58.00), Mean: 52.39, StdDev: 6.98 MMCR: Data Continuity: 1 Data recovery: 95.8% MWR: Data Continuity: 2 Data recovery: 99.9% MWR: Data Quality: 1 TB_30.000: 489/5683 out of range [0-300 K] AHSRL: Data Continuity: 0 Data recovery: 0.8% SONIC0: Data Continuity: 0 Data recovery: -7.8% SONIC1: Data Continuity: 1 Data recovery: 91.3% LICOR: Data Continuity: 1 Data recovery: 89.6% LICOR: Data Quality: 1 Temp: 6/791937 out of range [-60 to 30 m/s] Pres: 64/791937 out of range [900 to 1100 mb] DMS: RAID Status from dmesg 3w-9xxx: scsi0: Found a 3ware 9000 Storage Controller at 0xfb200000, IRQ: 201. 3w-9xxx: scsi0: Firmware FE9X 2.04.00.005, BIOS BE9X 2.03.01.047, Ports: 12. ---------------------------------------------------------