eurqclog.20080603.000000.txt Data Quality Summary for Eureka SEARCH Research Station Summary created: Wed Jun 4 00:29:02 2008 Value Interpretation -1: No assessment preformed. 0: All values out of range. 1: Some values in and out of range. 2: All data present and all values in range. ----------------------------------------------------------- STATUS FLAGS ----------------------------------------------------------- MMCR: Millimeter Cloud Radar Instrument Status: 1 Data Continuity: 2 Data Quality: -1 MWR: Microwave Radiometer Instrument Status: 1 Data Continuity: 1 Data Quality: 1 AHSRL: Arctic High Spectral Resolution Lidar Instrument Status: -1 Data Continuity: 2 Data Quality: -1 PAERI: Polar Atmos. Emitted Radiance Interferometer Instrument Status: -1 Data Continuity: -1 Data Quality: -1 SON0: Sonic Anemometer #0 Instrument Status: -1 Data Continuity: 1 Data Quality: 2 SON1: Sonic Anemometer #1 Instrument Status: -1 Data Continuity: 1 Data Quality: 2 LICOR: Licor Measurements Instrument Status: -1 Data Continuity: 1 Data Quality: 1 TOWERMET: Flux Tower Meteorological Measurements Instrument Status: -1 Data Continuity: -1 Data Quality: -1 DMS: Data Management System Filesystem Size Used Avail Use% Mounted on /dev/sda1 2.2T 1.7T 444G 79% /data /dev/sdb1 230G 153G 66G 71% /media/usbdisk /dev/sdc1 230G 93M 218G 1% /media/usbdisk1 ------------------------------------------------------------ --------------- ERROR SUMMARIES --------------- MMCR: Instrument Status: 1 20081550100Health.txt: temperature (outdoor): 1/0 out of range ( 0.00 to 0.00), Mean: ******, StdDev: 4.00 20081550800Health.txt: UPSBatteryVoltage: 1/120 out of range ( 24.00 to 58.00), Mean: 52.85, StdDev: 4.96 20081551200Health.txt: UPSInputVoltage : 2/120 out of range (108.00 to 126.00), Mean: 116.61, StdDev: 14.73 20081551300Health.txt: UPSInputVoltage : 1/120 out of range (108.00 to 126.00), Mean: 117.58, StdDev: 10.47 20081551800Health.txt: UPSOutputVoltage: 1/120 out of range (114.00 to 126.00), Mean: 117.34, StdDev: 10.91 20081551800Health.txt: UPSOutputCurrent: 2/120 out of range ( 0.00 to 10.00), Mean: 5.84, StdDev: 0.92 20081552200Health.txt: UPSInputVoltage : 1/120 out of range (108.00 to 126.00), Mean: 117.13, StdDev: 10.88 20081552200Health.txt: UPSOutputVoltage: 1/120 out of range (114.00 to 126.00), Mean: 117.30, StdDev: 10.92 20081552200Health.txt: UPSOutputCurrent: 1/120 out of range ( 0.00 to 10.00), Mean: 6.01, StdDev: 0.72 20081552200Health.txt: UPSBatteryVoltage: 1/120 out of range ( 24.00 to 58.00), Mean: 52.85, StdDev: 4.96 MMCR: Data Continuity: 2 Data recovery: 100.0% MWR: Instrument Status: 1 23.835 CAL: 2/112 out of range, [Tnd +/- 3K] 26.235 CAL: 2/112 out of range, [Tnd +/- 3K] MWR: Data Continuity: 1 Data recovery: 87.8% MWR: Data Quality: 1 TB_30.000: 102/4995 out of range [0-300 K] AHSRL: Data Continuity: 2 Data recovery: 98.8% SONIC0: Data Continuity: 1 Data recovery: 82.9% SONIC1: Data Continuity: 1 Data recovery: 87.0% LICOR: Data Continuity: 1 Data recovery: 84.6% LICOR: Data Quality: 1 CO2: 2/753816 out of range [0 to 1000 m/s] H2O: 6/753816 out of range [0 to 1000 m/s] Temp: 20/753816 out of range [-60 to 30 m/s] Pres: 84/753816 out of range [900 to 1100 mb] DMS: RAID Status from dmesg 3w-9xxx: scsi0: Found a 3ware 9000 Storage Controller at 0xfb200000, IRQ: 201. 3w-9xxx: scsi0: Firmware FE9X 2.04.00.005, BIOS BE9X 2.03.01.047, Ports: 12. ---------------------------------------------------------