eurqclog.20080811.000000.txt Data Quality Summary for Eureka SEARCH Research Station Summary created: Tue Aug 12 00:49:49 2008 Value Interpretation -1: No assessment preformed. 0: All values out of range. 1: Some values in and out of range. 2: All data present and all values in range. ----------------------------------------------------------- STATUS FLAGS ----------------------------------------------------------- MMCR: Millimeter Cloud Radar Instrument Status: 1 Data Continuity: 2 Data Quality: -1 MWR: Microwave Radiometer Instrument Status: 1 Data Continuity: 2 Data Quality: 2 AHSRL: Arctic High Spectral Resolution Lidar Instrument Status: -1 Data Continuity: -1 Data Quality: -1 PAERI: Polar Atmos. Emitted Radiance Interferometer Instrument Status: -1 Data Continuity: -1 Data Quality: -1 SON0: Sonic Anemometer #0 Instrument Status: -1 Data Continuity: 1 Data Quality: 1 SON1: Sonic Anemometer #1 Instrument Status: -1 Data Continuity: -1 Data Quality: -1 LICOR: Licor Measurements Instrument Status: -1 Data Continuity: 1 Data Quality: 1 TOWERMET: Flux Tower Meteorological Measurements Instrument Status: -1 Data Continuity: -1 Data Quality: -1 DMS: Data Management System Filesystem Size Used Avail Use% Mounted on /dev/sda1 2.2T 1.7T 450G 79% /data /dev/sdb1 230G 93M 218G 1% /media/usbdisk /dev/sdc1 230G 82G 137G 38% /media/usbdisk1 ------------------------------------------------------------ --------------- ERROR SUMMARIES --------------- MMCR: Instrument Status: 1 20082240100Health.txt: temperature (outdoor): 1/0 out of range ( 0.00 to 0.00), Mean: ******, StdDev: 3.00 20082240100Health.txt: UPSInputVoltage : 1/120 out of range (108.00 to 126.00), Mean: 119.08, StdDev: 11.06 20082240100Health.txt: UPSOutputVoltage: 1/120 out of range (114.00 to 126.00), Mean: 117.45, StdDev: 10.92 20082240100Health.txt: UPSOutputCurrent: 1/120 out of range ( 0.00 to 10.00), Mean: 5.70, StdDev: 0.66 20082240100Health.txt: UPSBatteryVoltage: 1/120 out of range ( 24.00 to 58.00), Mean: 52.85, StdDev: 4.96 20082240600Health.txt: UPSInputVoltage : 1/120 out of range (108.00 to 126.00), Mean: 119.06, StdDev: 11.05 20082240600Health.txt: UPSOutputVoltage: 1/120 out of range (114.00 to 126.00), Mean: 117.37, StdDev: 10.91 20082240600Health.txt: UPSOutputCurrent: 1/120 out of range ( 0.00 to 10.00), Mean: 5.69, StdDev: 0.65 20082241100Health.txt: UPSInputVoltage : 1/120 out of range (108.00 to 126.00), Mean: 118.98, StdDev: 11.05 20082241100Health.txt: UPSOutputVoltage: 1/120 out of range (114.00 to 126.00), Mean: 117.48, StdDev: 10.94 20082241100Health.txt: UPSOutputCurrent: 1/120 out of range ( 0.00 to 10.00), Mean: 5.81, StdDev: 0.72 20082241100Health.txt: UPSBatteryVoltage: 1/120 out of range ( 24.00 to 58.00), Mean: 52.85, StdDev: 4.96 20082241200Health.txt: UPSInputVoltage : 1/120 out of range (108.00 to 126.00), Mean: 119.08, StdDev: 11.06 20082241200Health.txt: UPSOutputVoltage: 1/120 out of range (114.00 to 126.00), Mean: 117.36, StdDev: 10.91 20082241300Health.txt: UPSOutputVoltage: 1/120 out of range (114.00 to 126.00), Mean: 117.45, StdDev: 10.92 20082241300Health.txt: UPSOutputCurrent: 1/120 out of range ( 0.00 to 10.00), Mean: 5.67, StdDev: 0.66 20082241700Health.txt: UPSInputVoltage : 2/120 out of range (108.00 to 126.00), Mean: 117.14, StdDev: 15.45 20082241700Health.txt: UPSOutputVoltage: 2/120 out of range (114.00 to 126.00), Mean: 116.28, StdDev: 15.34 20082241700Health.txt: UPSOutputCurrent: 1/120 out of range ( 0.00 to 10.00), Mean: 5.61, StdDev: 0.67 20082241700Health.txt: UPSBatteryVoltage: 1/120 out of range ( 24.00 to 58.00), Mean: 52.85, StdDev: 4.96 MMCR: Data Continuity: 2 Data recovery: 100.0% MWR: Instrument Status: 1 26.235 CAL: 1/8 out of range, [Tnd +/- 3K] MWR: Data Continuity: 2 Data recovery: 99.9% SONIC0: Data Continuity: 1 Data recovery: 95.8% SONIC0: Data Quality: 1 W: 42041/827961 out of range [-20 to 20 m/s] Tv: 42041/827961 out of range [-60 to 30 m/s] LICOR: Data Continuity: 1 Data recovery: 91.7% LICOR: Data Quality: 1 H2O: 162249/791984 out of range [0 to 1000 m/s] Temp: 30/791984 out of range [-60 to 30 m/s] Pres: 77145/791984 out of range [900 to 1100 mb] DMS: RAID Status from dmesg 3w-9xxx: scsi0: AEN: WARNING (0x04:0x0042): Error during read of primary DCB:port=5, error=0x204. 3w-9xxx: scsi0: AEN: ERROR (0x04:0x003A): Drive power on reset detected:port=5. 3w-9xxx: scsi0: AEN: WARNING (0x04:0x0006): Incomplete unit detected:unit=0. 3w-9xxx: scsi0: AEN: WARNING (0x04:0x0006): Incomplete unit detected:unit=1. 3w-9xxx: scsi0: Found a 3ware 9000 Storage Controller at 0xfb200000, IRQ: 201. 3w-9xxx: scsi0: Firmware FE9X 2.04.00.005, BIOS BE9X 2.03.01.047, Ports: 12. 3w-9xxx: scsi0: AEN: WARNING (0x04:0x0043): Latent error found in backup DCB:port=2, error=0x204. 3w-9xxx: scsi0: AEN: WARNING (0x04:0x0042): Error during read of primary DCB:port=5, error=0x204. ---------------------------------------------------------