eurqclog.20080821.000000.txt Data Quality Summary for Eureka SEARCH Research Station Summary created: Fri Aug 22 00:50:59 2008 Value Interpretation -1: No assessment preformed. 0: All values out of range. 1: Some values in and out of range. 2: All data present and all values in range. ----------------------------------------------------------- STATUS FLAGS ----------------------------------------------------------- MMCR: Millimeter Cloud Radar Instrument Status: 1 Data Continuity: 2 Data Quality: -1 MWR: Microwave Radiometer Instrument Status: 2 Data Continuity: 2 Data Quality: 1 AHSRL: Arctic High Spectral Resolution Lidar Instrument Status: -1 Data Continuity: -1 Data Quality: -1 PAERI: Polar Atmos. Emitted Radiance Interferometer Instrument Status: -1 Data Continuity: -1 Data Quality: -1 SON0: Sonic Anemometer #0 Instrument Status: -1 Data Continuity: 1 Data Quality: 2 SON1: Sonic Anemometer #1 Instrument Status: -1 Data Continuity: -1 Data Quality: -1 LICOR: Licor Measurements Instrument Status: -1 Data Continuity: 1 Data Quality: 1 TOWERMET: Flux Tower Meteorological Measurements Instrument Status: -1 Data Continuity: -1 Data Quality: -1 DMS: Data Management System Filesystem Size Used Avail Use% Mounted on /dev/sda1 2.2T 1.7T 449G 79% /data /dev/sdb1 230G 93M 218G 1% /media/usbdisk /dev/sdc1 230G 96G 123G 44% /media/usbdisk1 ------------------------------------------------------------ --------------- ERROR SUMMARIES --------------- MMCR: Instrument Status: 1 20082340100Health.txt: temperature (outdoor): 1/9 out of range ( 0.00 to 0.00), Mean: ******, StdDev: 4.00 20082340300Health.txt: UPSBatteryVoltage: 58/120 out of range ( 24.00 to 58.00), Mean: 55.81, StdDev: 2.61 20082340400Health.txt: UPSBatteryVoltage: 120/120 out of range ( 24.00 to 58.00), Mean: 58.50, StdDev: 0.00 20082340500Health.txt: UPSBatteryVoltage: 120/120 out of range ( 24.00 to 58.00), Mean: 58.50, StdDev: 0.00 20082340600Health.txt: UPSInputVoltage : 1/120 out of range (108.00 to 126.00), Mean: 119.12, StdDev: 11.06 20082340600Health.txt: UPSOutputVoltage: 1/120 out of range (114.00 to 126.00), Mean: 117.41, StdDev: 10.92 20082340600Health.txt: UPSOutputCurrent: 1/120 out of range ( 0.00 to 10.00), Mean: 5.74, StdDev: 0.69 20082340600Health.txt: UPSBatteryVoltage: 120/120 out of range ( 24.00 to 58.00), Mean: 58.00, StdDev: 5.43 20082340700Health.txt: UPSInputVoltage : 1/120 out of range (108.00 to 126.00), Mean: 119.15, StdDev: 11.07 20082340700Health.txt: UPSOutputVoltage: 1/120 out of range (114.00 to 126.00), Mean: 117.50, StdDev: 10.93 20082340700Health.txt: UPSOutputCurrent: 1/120 out of range ( 0.00 to 10.00), Mean: 5.74, StdDev: 0.68 20082340700Health.txt: UPSBatteryVoltage: 120/120 out of range ( 24.00 to 58.00), Mean: 58.00, StdDev: 5.43 20082340800Health.txt: UPSInputVoltage : 1/120 out of range (108.00 to 126.00), Mean: 119.37, StdDev: 11.09 20082340800Health.txt: UPSOutputVoltage: 1/120 out of range (114.00 to 126.00), Mean: 117.37, StdDev: 10.92 20082340800Health.txt: UPSOutputCurrent: 1/120 out of range ( 0.00 to 10.00), Mean: 5.65, StdDev: 0.65 20082340800Health.txt: UPSBatteryVoltage: 120/120 out of range ( 24.00 to 58.00), Mean: 58.00, StdDev: 5.43 20082340900Health.txt: UPSBatteryVoltage: 120/120 out of range ( 24.00 to 58.00), Mean: 58.50, StdDev: 0.00 20082341000Health.txt: UPSBatteryVoltage: 120/120 out of range ( 24.00 to 58.00), Mean: 58.50, StdDev: 0.00 20082341100Health.txt: UPSBatteryVoltage: 116/116 out of range ( 24.00 to 58.00), Mean: 58.50, StdDev: 0.00 20082341200Health.txt: UPSBatteryVoltage: 120/120 out of range ( 24.00 to 58.00), Mean: 58.50, StdDev: 0.00 20082341300Health.txt: UPSBatteryVoltage: 120/120 out of range ( 24.00 to 58.00), Mean: 58.50, StdDev: 0.00 20082341400Health.txt: UPSBatteryVoltage: 120/120 out of range ( 24.00 to 58.00), Mean: 58.50, StdDev: 0.00 20082341500Health.txt: UPSBatteryVoltage: 120/120 out of range ( 24.00 to 58.00), Mean: 58.50, StdDev: 0.00 20082341600Health.txt: UPSBatteryVoltage: 120/120 out of range ( 24.00 to 58.00), Mean: 58.50, StdDev: 0.00 20082341700Health.txt: UPSBatteryVoltage: 120/120 out of range ( 24.00 to 58.00), Mean: 58.50, StdDev: 0.00 20082341800Health.txt: UPSBatteryVoltage: 120/120 out of range ( 24.00 to 58.00), Mean: 58.00, StdDev: 5.43 20082341900Health.txt: UPSBatteryVoltage: 120/120 out of range ( 24.00 to 58.00), Mean: 58.50, StdDev: 0.00 20082342000Health.txt: UPSBatteryVoltage: 120/120 out of range ( 24.00 to 58.00), Mean: 58.50, StdDev: 0.00 20082342100Health.txt: UPSBatteryVoltage: 69/120 out of range ( 24.00 to 58.00), Mean: 56.42, StdDev: 2.46 20082342300Health.txt: UPSInputVoltage : 1/120 out of range (108.00 to 126.00), Mean: 119.03, StdDev: 11.05 20082342300Health.txt: UPSOutputVoltage: 1/120 out of range (114.00 to 126.00), Mean: 116.99, StdDev: 10.87 20082342300Health.txt: UPSOutputCurrent: 1/120 out of range ( 0.00 to 10.00), Mean: 5.47, StdDev: 0.64 20082342300Health.txt: UPSBatteryVoltage: 1/120 out of range ( 24.00 to 58.00), Mean: 52.85, StdDev: 4.96 MMCR: Data Continuity: 2 Data recovery: 100.0% MWR: Data Continuity: 2 Data recovery: 99.9% MWR: Data Quality: 1 TB_30.000: 79/5683 out of range [0-300 K] SONIC0: Data Continuity: 1 Data recovery: 95.8% LICOR: Data Continuity: 1 Data recovery: 91.7% LICOR: Data Quality: 1 Temp: 16/791984 out of range [-60 to 30 m/s] Pres: 28/791984 out of range [900 to 1100 mb] DMS: RAID Status from dmesg 3w-9xxx: scsi0: AEN: WARNING (0x04:0x0006): Incomplete unit detected:unit=0. 3w-9xxx: scsi0: AEN: WARNING (0x04:0x0006): Incomplete unit detected:unit=1. 3w-9xxx: scsi0: Found a 3ware 9000 Storage Controller at 0xfb200000, IRQ: 201. 3w-9xxx: scsi0: Firmware FE9X 2.04.00.005, BIOS BE9X 2.03.01.047, Ports: 12. 3w-9xxx: scsi0: AEN: WARNING (0x04:0x0042): Error during read of primary DCB:port=5, error=0x204. ---------------------------------------------------------