eurqclog.20080929.000000.txt Data Quality Summary for Eureka SEARCH Research Station Summary created: Tue Sep 30 01:30:10 2008 Value Interpretation -1: No assessment preformed. 0: All values out of range. 1: Some values in and out of range. 2: All data present and all values in range. ----------------------------------------------------------- STATUS FLAGS ----------------------------------------------------------- MMCR: Millimeter Cloud Radar Instrument Status: 1 Data Continuity: 1 Data Quality: -1 MWR: Microwave Radiometer Instrument Status: 2 Data Continuity: 1 Data Quality: 1 AHSRL: Arctic High Spectral Resolution Lidar Instrument Status: -1 Data Continuity: 1 Data Quality: -1 PAERI: Polar Atmos. Emitted Radiance Interferometer Instrument Status: -1 Data Continuity: -1 Data Quality: -1 SON0: Sonic Anemometer #0 Instrument Status: -1 Data Continuity: 1 Data Quality: 1 SON1: Sonic Anemometer #1 Instrument Status: -1 Data Continuity: 1 Data Quality: 1 LICOR: Licor Measurements Instrument Status: -1 Data Continuity: 1 Data Quality: 1 TOWERMET: Flux Tower Meteorological Measurements Instrument Status: -1 Data Continuity: -1 Data Quality: -1 DMS: Data Management System Filesystem Size Used Avail Use% Mounted on /dev/sda1 2.2T 1.6T 539G 75% /data /dev/sdb1 230G 5.3G 213G 3% /media/usbdisk /dev/sdc1 230G 175G 44G 80% /media/usbdisk1 ------------------------------------------------------------ --------------- ERROR SUMMARIES --------------- MMCR: Instrument Status: 1 20082730500Health.txt: UPSInputVoltage : 1/120 out of range (108.00 to 126.00), Mean: 117.04, StdDev: 10.87 20082730500Health.txt: UPSOutputVoltage: 1/120 out of range (114.00 to 126.00), Mean: 116.67, StdDev: 10.85 20082730500Health.txt: UPSOutputCurrent: 1/120 out of range ( 0.00 to 10.00), Mean: 6.05, StdDev: 0.68 20082730500Health.txt: UPSBatteryVoltage: 1/120 out of range ( 24.00 to 58.00), Mean: 52.85, StdDev: 4.96 20082730600Health.txt: UPSInputVoltage : 1/120 out of range (108.00 to 126.00), Mean: 116.99, StdDev: 10.86 20082730600Health.txt: UPSOutputVoltage: 1/120 out of range (114.00 to 126.00), Mean: 116.84, StdDev: 10.88 20082730600Health.txt: UPSOutputCurrent: 1/120 out of range ( 0.00 to 10.00), Mean: 6.13, StdDev: 0.73 20082730600Health.txt: UPSBatteryVoltage: 3/120 out of range ( 24.00 to 58.00), Mean: 51.94, StdDev: 8.51 20082731200Health.txt: UPSInputVoltage : 2/120 out of range (108.00 to 126.00), Mean: 115.79, StdDev: 15.27 20082731200Health.txt: UPSOutputVoltage: 2/120 out of range (114.00 to 126.00), Mean: 115.79, StdDev: 15.28 20082731200Health.txt: UPSOutputCurrent: 1/120 out of range ( 0.00 to 10.00), Mean: 6.03, StdDev: 0.68 20082731200Health.txt: UPSBatteryVoltage: 1/120 out of range ( 24.00 to 58.00), Mean: 52.85, StdDev: 4.96 20082731400Health.txt: UPSInputVoltage : 37/120 out of range (108.00 to 126.00), Mean: 83.58, StdDev: 52.44 20082731500Health.txt: UPSInputVoltage : 1/120 out of range (108.00 to 126.00), Mean: 117.78, StdDev: 10.48 20082731700Health.txt: UPSInputVoltage : 1/120 out of range (108.00 to 126.00), Mean: 117.97, StdDev: 10.96 20082731700Health.txt: UPSOutputVoltage: 1/120 out of range (114.00 to 126.00), Mean: 117.19, StdDev: 10.91 20082731700Health.txt: UPSOutputCurrent: 1/120 out of range ( 0.00 to 10.00), Mean: 6.18, StdDev: 0.70 20082731700Health.txt: UPSBatteryVoltage: 60/120 out of range ( 24.00 to 58.00), Mean: 57.21, StdDev: 5.43 20082731800Health.txt: UPSBatteryVoltage: 120/120 out of range ( 24.00 to 58.00), Mean: 58.50, StdDev: 0.00 20082731900Health.txt: UPSBatteryVoltage: 120/120 out of range ( 24.00 to 58.00), Mean: 58.50, StdDev: 0.00 20082732000Health.txt: UPSBatteryVoltage: 111/118 out of range ( 24.00 to 58.00), Mean: 58.28, StdDev: 0.88 MMCR: Data Continuity: 1 Data recovery: 95.8% MWR: Data Continuity: 1 Data recovery: 96.3% MWR: Data Quality: 1 TB_30.000: 195/5478 out of range [0-300 K] AHSRL: Data Continuity: 1 Data recovery: 77.4% SONIC0: Data Continuity: 1 Data recovery: 77.1% SONIC0: Data Quality: 1 W: 3061/666169 out of range [-20 to 20 m/s] Tv: 3061/666169 out of range [-60 to 30 m/s] SONIC1: Data Continuity: 1 Data recovery: 95.3% SONIC1: Data Quality: 1 U: 582/823258 out of range [-40 to 40 m/s] LICOR: Data Continuity: 1 Data recovery: 73.5% LICOR: Data Quality: 1 CO2: 1/659948 out of range [0 to 1000 m/s] H2O: 18647/659948 out of range [0 to 1000 m/s] Temp: 35/659948 out of range [-60 to 30 m/s] Pres: 29548/659948 out of range [900 to 1100 mb] DMS: RAID Status from dmesg 3w-9xxx: scsi0: AEN: WARNING (0x04:0x0006): Incomplete unit detected:unit=0. 3w-9xxx: scsi0: AEN: WARNING (0x04:0x0006): Incomplete unit detected:unit=1. 3w-9xxx: scsi0: Found a 3ware 9000 Storage Controller at 0xfb200000, IRQ: 201. 3w-9xxx: scsi0: Firmware FE9X 2.04.00.005, BIOS BE9X 2.03.01.047, Ports: 12. ---------------------------------------------------------