eurqclog.20081121.000000.txt Data Quality Summary for Eureka SEARCH Research Station Summary created: Sat Nov 22 01:37:15 2008 Value Interpretation -1: No assessment preformed. 0: All values out of range. 1: Some values in and out of range. 2: All data present and all values in range. ----------------------------------------------------------- STATUS FLAGS ----------------------------------------------------------- MMCR: Millimeter Cloud Radar Instrument Status: 1 Data Continuity: 1 Data Quality: -1 MWR: Microwave Radiometer Instrument Status: 2 Data Continuity: 2 Data Quality: 1 AHSRL: Arctic High Spectral Resolution Lidar Instrument Status: -1 Data Continuity: 1 Data Quality: -1 PAERI: Polar Atmos. Emitted Radiance Interferometer Instrument Status: -1 Data Continuity: -1 Data Quality: -1 SON0: Sonic Anemometer #0 Instrument Status: -1 Data Continuity: 1 Data Quality: 1 SON1: Sonic Anemometer #1 Instrument Status: -1 Data Continuity: 1 Data Quality: 1 LICOR: Licor Measurements Instrument Status: -1 Data Continuity: 1 Data Quality: 1 TOWERMET: Flux Tower Meteorological Measurements Instrument Status: -1 Data Continuity: -1 Data Quality: -1 DMS: Data Management System Filesystem Size Used Avail Use% Mounted on /dev/sda1 2.2T 1.6T 536G 75% /data /dev/sdb1 230G 132G 86G 61% /media/usbdisk /dev/sdc1 230G 93M 218G 1% /media/usbdisk1 ------------------------------------------------------------ --------------- ERROR SUMMARIES --------------- MMCR: Instrument Status: 1 20083261600Health.txt: UPSBatteryVoltage: 1/120 out of range ( 24.00 to 58.00), Mean: 52.85, StdDev: 4.96 MMCR: Data Continuity: 1 Data recovery: 91.7% MWR: Data Continuity: 2 Data recovery: 99.9% MWR: Data Quality: 1 TB_30.000: 159/5683 out of range [0-300 K] AHSRL: Data Continuity: 1 Data recovery: 88.6% SONIC0: Data Continuity: 1 Data recovery: 66.5% SONIC0: Data Quality: 1 U: 171250/733117 out of range [-40 to 40 m/s] V: 405315/733117 out of range [-40 to 40 m/s] W: 44578/733117 out of range [-20 to 20 m/s] Tv: 274191/733117 out of range [-60 to 30 m/s] SONIC1: Data Continuity: 1 Data recovery: 33.7% SONIC1: Data Quality: 1 U: 28414/290374 out of range [-40 to 40 m/s] V: 46892/290374 out of range [-40 to 40 m/s] W: 116410/290374 out of range [-20 to 20 m/s] Tv: 290372/290374 out of range [-60 to 30 m/s] LICOR: Data Continuity: 1 Data recovery: 54.2% LICOR: Data Quality: 1 CO2: 47/735936 out of range [0 to 1000 m/s] H2O: 735863/735936 out of range [0 to 1000 m/s] Temp: 505994/735936 out of range [-60 to 30 m/s] Pres: 721409/735936 out of range [900 to 1100 mb] DMS: RAID Status from dmesg 3w-9xxx: scsi0: AEN: WARNING (0x04:0x0006): Incomplete unit detected:unit=1. 3w-9xxx: scsi0: Found a 3ware 9000 Storage Controller at 0xfb200000, IRQ: 201. 3w-9xxx: scsi0: Firmware FE9X 2.04.00.005, BIOS BE9X 2.03.01.047, Ports: 12. ---------------------------------------------------------