eurqclog.20081228.000000.txt Data Quality Summary for Eureka SEARCH Research Station Summary created: Mon Dec 29 01:51:00 2008 Value Interpretation -1: No assessment preformed. 0: All values out of range. 1: Some values in and out of range. 2: All data present and all values in range. ----------------------------------------------------------- STATUS FLAGS ----------------------------------------------------------- MMCR: Millimeter Cloud Radar Instrument Status: 1 Data Continuity: 2 Data Quality: -1 MWR: Microwave Radiometer Instrument Status: -1 Data Continuity: -1 Data Quality: -1 AHSRL: Arctic High Spectral Resolution Lidar Instrument Status: -1 Data Continuity: 1 Data Quality: -1 PAERI: Polar Atmos. Emitted Radiance Interferometer Instrument Status: -1 Data Continuity: -1 Data Quality: -1 DMS: Data Management System Filesystem Size Used Avail Use% Mounted on /dev/sda1 2.2T 1.6T 496G 77% /data /dev/sdc1 230G 33G 186G 15% /media/usbdisk /dev/sdb1 230G 93M 218G 1% /media/usbdisk1 ------------------------------------------------------------ --------------- ERROR SUMMARIES --------------- MMCR: Instrument Status: 1 20083630200Health.txt: UPSBatteryVoltage: 1/120 out of range ( 24.00 to 58.00), Mean: 52.85, StdDev: 4.96 20083630400Health.txt: UPSInputVoltage : 1/120 out of range (108.00 to 126.00), Mean: 117.12, StdDev: 10.88 20083630400Health.txt: UPSOutputVoltage: 1/120 out of range (114.00 to 126.00), Mean: 117.61, StdDev: 10.93 20083630400Health.txt: UPSOutputCurrent: 1/120 out of range ( 0.00 to 10.00), Mean: 6.15, StdDev: 0.71 20083630400Health.txt: UPSBatteryVoltage: 1/120 out of range ( 24.00 to 58.00), Mean: 52.85, StdDev: 4.96 20083630800Health.txt: UPSOutputVoltage: 2/120 out of range (114.00 to 126.00), Mean: 116.49, StdDev: 15.37 20083630800Health.txt: UPSOutputCurrent: 2/120 out of range ( 0.00 to 10.00), Mean: 6.08, StdDev: 0.96 20083631800Health.txt: UPSInputVoltage : 1/120 out of range (108.00 to 126.00), Mean: 117.00, StdDev: 10.86 20083631800Health.txt: UPSOutputVoltage: 1/120 out of range (114.00 to 126.00), Mean: 117.58, StdDev: 10.94 20083631800Health.txt: UPSOutputCurrent: 1/120 out of range ( 0.00 to 10.00), Mean: 6.14, StdDev: 0.72 20083631800Health.txt: UPSBatteryVoltage: 1/120 out of range ( 24.00 to 58.00), Mean: 52.85, StdDev: 4.96 20083632000Health.txt: UPSBatteryVoltage: 2/116 out of range ( 24.00 to 58.00), Mean: 52.36, StdDev: 7.10 AHSRL: Data Continuity: 1 Data recovery: 37.7% DMS: RAID Status from dmesg 3w-9xxx: scsi0: AEN: WARNING (0x04:0x0042): Error during read of primary DCB:port=2, error=0x204. 3w-9xxx: scsi0: Found a 3ware 9000 Storage Controller at 0xfb200000, IRQ: 201. 3w-9xxx: scsi0: Firmware FE9X 2.04.00.005, BIOS BE9X 2.03.01.047, Ports: 12. ---------------------------------------------------------