eurqclog.20090319.000000.txt Data Quality Summary for Eureka SEARCH Research Station Summary created: Fri Mar 20 01:56:17 2009 Value Interpretation -1: No assessment preformed. 0: All values out of range. 1: Some values in and out of range. 2: All data present and all values in range. ----------------------------------------------------------- STATUS FLAGS ----------------------------------------------------------- MMCR: Millimeter Cloud Radar Instrument Status: 1 Data Continuity: 1 Data Quality: -1 MWR: Microwave Radiometer Instrument Status: -1 Data Continuity: 2 Data Quality: 1 AHSRL: Arctic High Spectral Resolution Lidar Instrument Status: -1 Data Continuity: 1 Data Quality: -1 PAERI: Polar Atmos. Emitted Radiance Interferometer Instrument Status: -1 Data Continuity: -1 Data Quality: -1 SON0: Sonic Anemometer #0 Instrument Status: -1 Data Continuity: 2 Data Quality: 2 SON1: Sonic Anemometer #1 Instrument Status: -1 Data Continuity: 1 Data Quality: 1 LICOR: Licor Measurements Instrument Status: -1 Data Continuity: 1 Data Quality: 1 TOWERMET: Flux Tower Meteorological Measurements Instrument Status: -1 Data Continuity: -1 Data Quality: -1 DMS: Data Management System Filesystem Size Used Avail Use% Mounted on /dev/sda1 2.2T 1.7T 428G 80% /data /dev/sdb1 230G 52G 167G 24% /media/usbdisk /dev/sdc1 230G 93M 218G 1% /media/usbdisk1 ------------------------------------------------------------ --------------- ERROR SUMMARIES --------------- MMCR: Instrument Status: 1 20090780300Health.txt: UPSOutputVoltage: 1/120 out of range (114.00 to 126.00), Mean: 117.81, StdDev: 10.96 20090780300Health.txt: UPSOutputCurrent: 1/120 out of range ( 0.00 to 10.00), Mean: 6.12, StdDev: 0.72 20090780300Health.txt: UPSBatteryVoltage: 50/120 out of range ( 24.00 to 58.00), Mean: 55.47, StdDev: 2.57 20090780400Health.txt: UPSOutputCurrent: 1/120 out of range ( 0.00 to 10.00), Mean: 6.33, StdDev: 0.80 20090780400Health.txt: UPSBatteryVoltage: 120/120 out of range ( 24.00 to 58.00), Mean: 58.50, StdDev: 0.00 20090780500Health.txt: UPSBatteryVoltage: 120/120 out of range ( 24.00 to 58.00), Mean: 58.50, StdDev: 0.00 20090780600Health.txt: UPSBatteryVoltage: 120/120 out of range ( 24.00 to 58.00), Mean: 58.50, StdDev: 0.00 20090780700Health.txt: UPSBatteryVoltage: 120/120 out of range ( 24.00 to 58.00), Mean: 58.50, StdDev: 0.00 20090780800Health.txt: UPSBatteryVoltage: 120/120 out of range ( 24.00 to 58.00), Mean: 58.50, StdDev: 0.00 20090780900Health.txt: UPSBatteryVoltage: 120/120 out of range ( 24.00 to 58.00), Mean: 58.50, StdDev: 0.00 20090781000Health.txt: UPSInputVoltage : 2/120 out of range (108.00 to 126.00), Mean: 116.82, StdDev: 15.41 20090781000Health.txt: UPSOutputVoltage: 2/120 out of range (114.00 to 126.00), Mean: 116.67, StdDev: 15.39 20090781000Health.txt: UPSOutputCurrent: 1/120 out of range ( 0.00 to 10.00), Mean: 6.10, StdDev: 0.69 20090781000Health.txt: UPSBatteryVoltage: 120/120 out of range ( 24.00 to 58.00), Mean: 58.50, StdDev: 0.00 20090781100Health.txt: UPSBatteryVoltage: 120/120 out of range ( 24.00 to 58.00), Mean: 58.50, StdDev: 0.00 20090781200Health.txt: UPSBatteryVoltage: 120/120 out of range ( 24.00 to 58.00), Mean: 58.50, StdDev: 0.00 20090781300Health.txt: UPSBatteryVoltage: 120/120 out of range ( 24.00 to 58.00), Mean: 58.50, StdDev: 0.00 20090781400Health.txt: UPSBatteryVoltage: 120/120 out of range ( 24.00 to 58.00), Mean: 58.50, StdDev: 0.00 20090781500Health.txt: UPSBatteryVoltage: 120/120 out of range ( 24.00 to 58.00), Mean: 58.50, StdDev: 0.00 20090781600Health.txt: UPSBatteryVoltage: 120/120 out of range ( 24.00 to 58.00), Mean: 58.50, StdDev: 0.00 20090781700Health.txt: UPSBatteryVoltage: 120/120 out of range ( 24.00 to 58.00), Mean: 58.50, StdDev: 0.00 20090781800Health.txt: UPSBatteryVoltage: 120/120 out of range ( 24.00 to 58.00), Mean: 58.50, StdDev: 0.00 20090781900Health.txt: UPSBatteryVoltage: 120/120 out of range ( 24.00 to 58.00), Mean: 58.50, StdDev: 0.00 20090782000Health.txt: UPSBatteryVoltage: 120/120 out of range ( 24.00 to 58.00), Mean: 58.50, StdDev: 0.00 20090782100Health.txt: UPSBatteryVoltage: 70/120 out of range ( 24.00 to 58.00), Mean: 56.59, StdDev: 2.36 MMCR: Data Continuity: 1 Data recovery: 95.8% MWR: Data Continuity: 2 Data recovery: 99.9% MWR: Data Quality: 1 TB_30.000: 536/5683 out of range [0-300 K] AHSRL: Data Continuity: 1 Data recovery: 94.7% SONIC0: Data Continuity: 2 Data recovery: 100.0% SONIC1: Data Continuity: 1 Data recovery: 95.8% SONIC1: Data Quality: 1 U: 544168/827952 out of range [-40 to 40 m/s] W: 14624/827952 out of range [-20 to 20 m/s] Tv: 827952/827952 out of range [-60 to 30 m/s] LICOR: Data Continuity: 1 Data recovery: 95.8% LICOR: Data Quality: 1 H2O: 493380/827984 out of range [0 to 1000 m/s] Temp: 1/827984 out of range [-60 to 30 m/s] Pres: 716690/827984 out of range [900 to 1100 mb] DMS: RAID Status from dmesg 3w-9xxx: scsi0: AEN: WARNING (0x04:0x0006): Incomplete unit detected:unit=2. 3w-9xxx: scsi0: Found a 3ware 9000 Storage Controller at 0xfb200000, IRQ: 201. 3w-9xxx: scsi0: Firmware FE9X 2.04.00.005, BIOS BE9X 2.03.01.047, Ports: 12. ---------------------------------------------------------