eurqclog.20130208.000000.txt Data Quality Summary for Eureka SEARCH Research Station Summary created: Sat Feb 9 08:10:49 2013 Value Interpretation -1: No assessment preformed. 0: All values out of range. 1: Some values in and out of range. 2: All data present and all values in range. ----------------------------------------------------------- STATUS FLAGS ----------------------------------------------------------- MMCR: Millimeter Cloud Radar Instrument Status: 1 Data Continuity: 1 Data Quality: -1 MWR: Microwave Radiometer Instrument Status: -1 Data Continuity: -1 Data Quality: -1 AHSRL: Arctic High Spectral Resolution Lidar Instrument Status: -1 Data Continuity: -1 Data Quality: -1 PAERI: Polar Atmos. Emitted Radiance Interferometer Instrument Status: -1 Data Continuity: -1 Data Quality: -1 SON0: Sonic Anemometer #0 Instrument Status: -1 Data Continuity: -1 Data Quality: -1 SON1: Sonic Anemometer #1 Instrument Status: -1 Data Continuity: -1 Data Quality: -1 LICOR: Licor Measurements Instrument Status: -1 Data Continuity: -1 Data Quality: -1 TOWERMET: Flux Tower Meteorological Measurements Instrument Status: -1 Data Continuity: -1 Data Quality: -1 DMS: Data Management System ------------------------------------------------------------ --------------- ERROR SUMMARIES --------------- MMCR: Instrument Status: 1 20130390200Health.txt: temperature (outdoor): 1/9 out of range ( 0.00 to 0.00), Mean: ******, StdDev: 8.00 20130390400Health.txt: UPSInputVoltage : 1/120 out of range (108.00 to 126.00), Mean: 117.78, StdDev: 10.96 20130390400Health.txt: UPSOutputVoltage: 1/120 out of range (114.00 to 126.00), Mean: 116.08, StdDev: 10.78 20130390400Health.txt: UPSOutputCurrent: 1/120 out of range ( 0.00 to 10.00), Mean: 5.65, StdDev: 0.63 20130390500Health.txt: UPSOutputVoltage: 1/120 out of range (114.00 to 126.00), Mean: 116.08, StdDev: 10.78 20130390500Health.txt: UPSOutputCurrent: 1/120 out of range ( 0.00 to 10.00), Mean: 5.67, StdDev: 0.64 20130390500Health.txt: UPSBatteryVoltage: 2/120 out of range ( 24.00 to 58.00), Mean: 52.39, StdDev: 6.98 20130390800Health.txt: UPSBatteryVoltage: 84/120 out of range ( 24.00 to 58.00), Mean: 56.94, StdDev: 2.39 20130390900Health.txt: UPSBatteryVoltage: 120/120 out of range ( 24.00 to 58.00), Mean: 58.50, StdDev: 0.00 20130391000Health.txt: UPSBatteryVoltage: 120/120 out of range ( 24.00 to 58.00), Mean: 58.50, StdDev: 0.00 20130391100Health.txt: UPSBatteryVoltage: 120/120 out of range ( 24.00 to 58.00), Mean: 58.50, StdDev: 0.00 20130391200Health.txt: UPSBatteryVoltage: 120/120 out of range ( 24.00 to 58.00), Mean: 58.50, StdDev: 0.00 20130391300Health.txt: UPSBatteryVoltage: 120/120 out of range ( 24.00 to 58.00), Mean: 58.50, StdDev: 0.00 20130391400Health.txt: UPSBatteryVoltage: 120/120 out of range ( 24.00 to 58.00), Mean: 58.50, StdDev: 0.00 20130391500Health.txt: UPSBatteryVoltage: 120/120 out of range ( 24.00 to 58.00), Mean: 58.50, StdDev: 0.00 20130391600Health.txt: UPSInputVoltage : 1/121 out of range (108.00 to 126.00), Mean: 117.58, StdDev: 10.88 20130391600Health.txt: UPSOutputVoltage: 1/121 out of range (114.00 to 126.00), Mean: 116.09, StdDev: 10.74 20130391600Health.txt: UPSOutputCurrent: 1/121 out of range ( 0.00 to 10.00), Mean: 5.63, StdDev: 0.63 20130391600Health.txt: UPSBatteryVoltage: 121/121 out of range ( 24.00 to 58.00), Mean: 58.01, StdDev: 5.41 20130391700Health.txt: UPSBatteryVoltage: 119/119 out of range ( 24.00 to 58.00), Mean: 58.50, StdDev: 0.00 20130391800Health.txt: UPSInputVoltage : 1/120 out of range (108.00 to 126.00), Mean: 117.56, StdDev: 10.93 20130391800Health.txt: UPSOutputVoltage: 1/120 out of range (114.00 to 126.00), Mean: 116.26, StdDev: 10.81 20130391800Health.txt: UPSOutputCurrent: 1/120 out of range ( 0.00 to 10.00), Mean: 5.61, StdDev: 0.63 20130391800Health.txt: UPSBatteryVoltage: 120/120 out of range ( 24.00 to 58.00), Mean: 58.00, StdDev: 5.43 20130391900Health.txt: UPSBatteryVoltage: 120/120 out of range ( 24.00 to 58.00), Mean: 58.50, StdDev: 0.00 20130392000Health.txt: UPSBatteryVoltage: 120/120 out of range ( 24.00 to 58.00), Mean: 58.50, StdDev: 0.00 20130392100Health.txt: UPSInputVoltage : 1/120 out of range (108.00 to 126.00), Mean: 117.58, StdDev: 10.94 20130392100Health.txt: UPSOutputVoltage: 1/120 out of range (114.00 to 126.00), Mean: 116.16, StdDev: 10.79 20130392100Health.txt: UPSOutputCurrent: 1/120 out of range ( 0.00 to 10.00), Mean: 5.72, StdDev: 0.65 20130392100Health.txt: UPSBatteryVoltage: 120/120 out of range ( 24.00 to 58.00), Mean: 58.00, StdDev: 5.43 20130392200Health.txt: UPSOutputCurrent: 1/120 out of range ( 0.00 to 10.00), Mean: 5.67, StdDev: 0.64 20130392200Health.txt: UPSBatteryVoltage: 120/120 out of range ( 24.00 to 58.00), Mean: 58.00, StdDev: 5.43 20130392300Health.txt: UPSBatteryVoltage: 120/120 out of range ( 24.00 to 58.00), Mean: 58.50, StdDev: 0.00 MMCR: Data Continuity: 1 Data recovery: 95.8% ---------------------------------------------------------