eurqclog.20130209.000000.txt Data Quality Summary for Eureka SEARCH Research Station Summary created: Sun Feb 10 08:10:46 2013 Value Interpretation -1: No assessment preformed. 0: All values out of range. 1: Some values in and out of range. 2: All data present and all values in range. ----------------------------------------------------------- STATUS FLAGS ----------------------------------------------------------- MMCR: Millimeter Cloud Radar Instrument Status: 1 Data Continuity: 1 Data Quality: -1 MWR: Microwave Radiometer Instrument Status: -1 Data Continuity: -1 Data Quality: -1 AHSRL: Arctic High Spectral Resolution Lidar Instrument Status: -1 Data Continuity: -1 Data Quality: -1 PAERI: Polar Atmos. Emitted Radiance Interferometer Instrument Status: -1 Data Continuity: -1 Data Quality: -1 SON0: Sonic Anemometer #0 Instrument Status: -1 Data Continuity: -1 Data Quality: -1 SON1: Sonic Anemometer #1 Instrument Status: -1 Data Continuity: -1 Data Quality: -1 LICOR: Licor Measurements Instrument Status: -1 Data Continuity: -1 Data Quality: -1 TOWERMET: Flux Tower Meteorological Measurements Instrument Status: -1 Data Continuity: -1 Data Quality: -1 DMS: Data Management System ------------------------------------------------------------ --------------- ERROR SUMMARIES --------------- MMCR: Instrument Status: 1 20130400200Health.txt: UPSBatteryVoltage: 37/120 out of range ( 24.00 to 58.00), Mean: 55.20, StdDev: 2.34 20130400400Health.txt: UPSInputVoltage : 1/120 out of range (108.00 to 126.00), Mean: 118.04, StdDev: 10.96 20130400400Health.txt: UPSOutputVoltage: 1/120 out of range (114.00 to 126.00), Mean: 116.07, StdDev: 10.78 20130400400Health.txt: UPSOutputCurrent: 1/120 out of range ( 0.00 to 10.00), Mean: 5.67, StdDev: 0.63 20130400400Health.txt: UPSBatteryVoltage: 1/120 out of range ( 24.00 to 58.00), Mean: 52.85, StdDev: 4.96 20130400900Health.txt: UPSInputVoltage : 1/120 out of range (108.00 to 126.00), Mean: 118.06, StdDev: 10.97 20130400900Health.txt: UPSOutputVoltage: 1/120 out of range (114.00 to 126.00), Mean: 116.08, StdDev: 10.78 20130400900Health.txt: UPSOutputCurrent: 1/120 out of range ( 0.00 to 10.00), Mean: 5.75, StdDev: 0.66 20130400900Health.txt: UPSBatteryVoltage: 1/120 out of range ( 24.00 to 58.00), Mean: 52.85, StdDev: 4.96 20130401000Health.txt: UPSOutputCurrent: 1/120 out of range ( 0.00 to 10.00), Mean: 5.66, StdDev: 0.64 20130401000Health.txt: UPSBatteryVoltage: 1/120 out of range ( 24.00 to 58.00), Mean: 52.85, StdDev: 4.96 20130401100Health.txt: UPSInputVoltage : 1/120 out of range (108.00 to 126.00), Mean: 117.82, StdDev: 10.96 20130401100Health.txt: UPSOutputVoltage: 1/120 out of range (114.00 to 126.00), Mean: 116.06, StdDev: 10.78 20130401100Health.txt: UPSOutputCurrent: 1/120 out of range ( 0.00 to 10.00), Mean: 5.65, StdDev: 0.63 20130401100Health.txt: UPSBatteryVoltage: 1/120 out of range ( 24.00 to 58.00), Mean: 52.85, StdDev: 4.96 20130401700Health.txt: UPSInputVoltage : 1/120 out of range (108.00 to 126.00), Mean: 117.43, StdDev: 10.91 20130401700Health.txt: UPSOutputVoltage: 1/120 out of range (114.00 to 126.00), Mean: 116.11, StdDev: 10.79 20130401700Health.txt: UPSOutputCurrent: 1/120 out of range ( 0.00 to 10.00), Mean: 5.67, StdDev: 0.63 20130401700Health.txt: UPSBatteryVoltage: 2/120 out of range ( 24.00 to 58.00), Mean: 52.39, StdDev: 6.98 20130401800Health.txt: UPSInputVoltage : 1/120 out of range (108.00 to 126.00), Mean: 117.53, StdDev: 10.93 20130401800Health.txt: UPSOutputVoltage: 1/120 out of range (114.00 to 126.00), Mean: 116.08, StdDev: 10.78 20130401800Health.txt: UPSOutputCurrent: 1/120 out of range ( 0.00 to 10.00), Mean: 5.67, StdDev: 0.64 20130401800Health.txt: UPSBatteryVoltage: 1/120 out of range ( 24.00 to 58.00), Mean: 52.85, StdDev: 4.96 MMCR: Data Continuity: 1 Data recovery: 95.8% ---------------------------------------------------------