eurqclog.20130309.000000.txt Data Quality Summary for Eureka SEARCH Research Station Summary created: Sun Mar 10 08:10:49 2013 Value Interpretation -1: No assessment preformed. 0: All values out of range. 1: Some values in and out of range. 2: All data present and all values in range. ----------------------------------------------------------- STATUS FLAGS ----------------------------------------------------------- MMCR: Millimeter Cloud Radar Instrument Status: 1 Data Continuity: 1 Data Quality: -1 MWR: Microwave Radiometer Instrument Status: -1 Data Continuity: -1 Data Quality: -1 AHSRL: Arctic High Spectral Resolution Lidar Instrument Status: -1 Data Continuity: -1 Data Quality: -1 PAERI: Polar Atmos. Emitted Radiance Interferometer Instrument Status: -1 Data Continuity: -1 Data Quality: -1 SON0: Sonic Anemometer #0 Instrument Status: -1 Data Continuity: -1 Data Quality: -1 SON1: Sonic Anemometer #1 Instrument Status: -1 Data Continuity: -1 Data Quality: -1 LICOR: Licor Measurements Instrument Status: -1 Data Continuity: -1 Data Quality: -1 TOWERMET: Flux Tower Meteorological Measurements Instrument Status: -1 Data Continuity: -1 Data Quality: -1 DMS: Data Management System ------------------------------------------------------------ --------------- ERROR SUMMARIES --------------- MMCR: Instrument Status: 1 20130680200Health.txt: UPSBatteryVoltage: 2/120 out of range ( 24.00 to 58.00), Mean: 52.39, StdDev: 6.98 20130680900Health.txt: UPSOutputCurrent: 1/120 out of range ( 0.00 to 10.00), Mean: 5.27, StdDev: 0.61 20130681900Health.txt: UPSOutputCurrent: 1/120 out of range ( 0.00 to 10.00), Mean: 5.28, StdDev: 0.61 MMCR: Data Continuity: 1 Data recovery: 95.8% ---------------------------------------------------------