eurqclog.20130310.000000.txt Data Quality Summary for Eureka SEARCH Research Station Summary created: Mon Mar 11 08:10:48 2013 Value Interpretation -1: No assessment preformed. 0: All values out of range. 1: Some values in and out of range. 2: All data present and all values in range. ----------------------------------------------------------- STATUS FLAGS ----------------------------------------------------------- MMCR: Millimeter Cloud Radar Instrument Status: 1 Data Continuity: 1 Data Quality: -1 MWR: Microwave Radiometer Instrument Status: -1 Data Continuity: -1 Data Quality: -1 AHSRL: Arctic High Spectral Resolution Lidar Instrument Status: -1 Data Continuity: -1 Data Quality: -1 PAERI: Polar Atmos. Emitted Radiance Interferometer Instrument Status: -1 Data Continuity: -1 Data Quality: -1 SON0: Sonic Anemometer #0 Instrument Status: -1 Data Continuity: -1 Data Quality: -1 SON1: Sonic Anemometer #1 Instrument Status: -1 Data Continuity: -1 Data Quality: -1 LICOR: Licor Measurements Instrument Status: -1 Data Continuity: -1 Data Quality: -1 TOWERMET: Flux Tower Meteorological Measurements Instrument Status: -1 Data Continuity: -1 Data Quality: -1 DMS: Data Management System ------------------------------------------------------------ --------------- ERROR SUMMARIES --------------- MMCR: Instrument Status: 1 20130690200Health.txt: UPSOutputVoltage: 1/120 out of range (114.00 to 126.00), Mean: 116.42, StdDev: 10.82 20130690700Health.txt: UPSInputVoltage : 1/120 out of range (108.00 to 126.00), Mean: 117.52, StdDev: 10.93 20130690800Health.txt: UPSBatteryVoltage: 82/120 out of range ( 24.00 to 58.00), Mean: 56.85, StdDev: 2.43 20130690900Health.txt: UPSBatteryVoltage: 120/120 out of range ( 24.00 to 58.00), Mean: 57.51, StdDev: 7.65 20130691000Health.txt: UPSBatteryVoltage: 120/120 out of range ( 24.00 to 58.00), Mean: 58.50, StdDev: 0.00 20130691100Health.txt: UPSBatteryVoltage: 120/120 out of range ( 24.00 to 58.00), Mean: 58.50, StdDev: 0.00 20130691200Health.txt: UPSBatteryVoltage: 120/120 out of range ( 24.00 to 58.00), Mean: 58.50, StdDev: 0.00 20130691300Health.txt: UPSInputVoltage : 1/120 out of range (108.00 to 126.00), Mean: 117.47, StdDev: 10.92 20130691300Health.txt: UPSOutputVoltage: 1/120 out of range (114.00 to 126.00), Mean: 116.38, StdDev: 10.82 20130691300Health.txt: UPSOutputCurrent: 2/120 out of range ( 0.00 to 10.00), Mean: 5.22, StdDev: 0.84 20130691300Health.txt: UPSBatteryVoltage: 120/120 out of range ( 24.00 to 58.00), Mean: 58.50, StdDev: 0.00 20130691400Health.txt: UPSOutputCurrent: 1/120 out of range ( 0.00 to 10.00), Mean: 5.28, StdDev: 0.61 20130691400Health.txt: UPSBatteryVoltage: 120/120 out of range ( 24.00 to 58.00), Mean: 58.00, StdDev: 5.43 20130691500Health.txt: UPSBatteryVoltage: 120/120 out of range ( 24.00 to 58.00), Mean: 58.50, StdDev: 0.00 20130691600Health.txt: UPSBatteryVoltage: 120/120 out of range ( 24.00 to 58.00), Mean: 58.50, StdDev: 0.00 20130691700Health.txt: UPSBatteryVoltage: 120/120 out of range ( 24.00 to 58.00), Mean: 58.50, StdDev: 0.00 20130691800Health.txt: UPSBatteryVoltage: 120/120 out of range ( 24.00 to 58.00), Mean: 58.50, StdDev: 0.00 20130691900Health.txt: UPSBatteryVoltage: 120/120 out of range ( 24.00 to 58.00), Mean: 58.50, StdDev: 0.00 20130692000Health.txt: UPSBatteryVoltage: 120/120 out of range ( 24.00 to 58.00), Mean: 58.50, StdDev: 0.00 20130692100Health.txt: UPSBatteryVoltage: 120/120 out of range ( 24.00 to 58.00), Mean: 57.01, StdDev: 9.33 20130692200Health.txt: UPSBatteryVoltage: 120/120 out of range ( 24.00 to 58.00), Mean: 58.50, StdDev: 0.00 20130692300Health.txt: UPSBatteryVoltage: 120/120 out of range ( 24.00 to 58.00), Mean: 58.50, StdDev: 0.00 MMCR: Data Continuity: 1 Data recovery: 95.8% ---------------------------------------------------------