eurqclog.20130403.000000.txt Data Quality Summary for Eureka SEARCH Research Station Summary created: Thu Apr 4 08:12:30 2013 Value Interpretation -1: No assessment preformed. 0: All values out of range. 1: Some values in and out of range. 2: All data present and all values in range. ----------------------------------------------------------- STATUS FLAGS ----------------------------------------------------------- MMCR: Millimeter Cloud Radar Instrument Status: 1 Data Continuity: 1 Data Quality: -1 MWR: Microwave Radiometer Instrument Status: 1 Data Continuity: 2 Data Quality: 1 AHSRL: Arctic High Spectral Resolution Lidar Instrument Status: -1 Data Continuity: -1 Data Quality: -1 PAERI: Polar Atmos. Emitted Radiance Interferometer Instrument Status: -1 Data Continuity: -1 Data Quality: -1 SON0: Sonic Anemometer #0 Instrument Status: -1 Data Continuity: 2 Data Quality: 1 SON1: Sonic Anemometer #1 Instrument Status: -1 Data Continuity: 1 Data Quality: 1 LICOR: Licor Measurements Instrument Status: -1 Data Continuity: 2 Data Quality: 1 TOWERMET: Flux Tower Meteorological Measurements Instrument Status: -1 Data Continuity: -1 Data Quality: -1 DMS: Data Management System ------------------------------------------------------------ --------------- ERROR SUMMARIES --------------- MMCR: Instrument Status: 1 20130930200Health.txt: UPSBatteryVoltage: 1/120 out of range ( 24.00 to 58.00), Mean: 52.85, StdDev: 4.96 20130930700Health.txt: UPSOutputVoltage: 1/120 out of range (114.00 to 126.00), Mean: 116.30, StdDev: 10.81 20130930700Health.txt: UPSOutputCurrent: 1/120 out of range ( 0.00 to 10.00), Mean: 5.35, StdDev: 0.63 20130931200Health.txt: UPSBatteryVoltage: 1/120 out of range ( 24.00 to 58.00), Mean: 52.85, StdDev: 4.96 20130931800Health.txt: UPSInputVoltage : 1/121 out of range (108.00 to 126.00), Mean: 117.18, StdDev: 10.84 20130931800Health.txt: UPSOutputVoltage: 1/121 out of range (114.00 to 126.00), Mean: 116.49, StdDev: 10.79 20130931800Health.txt: UPSOutputCurrent: 1/121 out of range ( 0.00 to 10.00), Mean: 5.32, StdDev: 0.63 20130931900Health.txt: UPSInputVoltage : 1/120 out of range (108.00 to 126.00), Mean: 117.20, StdDev: 10.90 20130931900Health.txt: UPSOutputVoltage: 1/120 out of range (114.00 to 126.00), Mean: 116.42, StdDev: 10.82 20130931900Health.txt: UPSOutputCurrent: 1/120 out of range ( 0.00 to 10.00), Mean: 5.29, StdDev: 0.61 20130931900Health.txt: UPSBatteryVoltage: 2/120 out of range ( 24.00 to 58.00), Mean: 52.39, StdDev: 6.98 20130932300Health.txt: UPSOutputVoltage: 1/120 out of range (114.00 to 126.00), Mean: 116.31, StdDev: 10.81 20130932300Health.txt: UPSOutputCurrent: 1/120 out of range ( 0.00 to 10.00), Mean: 5.28, StdDev: 0.61 MMCR: Data Continuity: 1 Data recovery: 95.8% MWR: Instrument Status: 1 30.000 CAL: 40/40 out of range, [Tnd +/- 3K] MWR: Data Continuity: 2 Data recovery: 99.9% MWR: Data Quality: 1 TB_30.000: 5486/5683 out of range [0-300 K] SONIC0: Data Continuity: 2 Data recovery: 100.0% SONIC0: Data Quality: 1 V: 697/863884 out of range [-40 to 40 m/s] SONIC1: Data Continuity: 1 Data recovery: 95.8% SONIC1: Data Quality: 1 U: 179525/827954 out of range [-40 to 40 m/s] LICOR: Data Continuity: 2 Data recovery: 100.0% LICOR: Data Quality: 1 H2O: 37272/863950 out of range [0 to 1000 m/s] Temp: 4/863950 out of range [-60 to 30 m/s] Pres: 625874/863950 out of range [900 to 1100 mb] ---------------------------------------------------------