eurqclog.20131212.000000.txt Data Quality Summary for Eureka SEARCH Research Station Summary created: Fri Dec 13 08:11:14 2013 Value Interpretation -1: No assessment preformed. 0: All values out of range. 1: Some values in and out of range. 2: All data present and all values in range. ----------------------------------------------------------- STATUS FLAGS ----------------------------------------------------------- MMCR: Millimeter Cloud Radar Instrument Status: 1 Data Continuity: 1 Data Quality: -1 MWR: Microwave Radiometer Instrument Status: -1 Data Continuity: 2 Data Quality: 1 AHSRL: Arctic High Spectral Resolution Lidar Instrument Status: -1 Data Continuity: -1 Data Quality: -1 PAERI: Polar Atmos. Emitted Radiance Interferometer Instrument Status: -1 Data Continuity: -1 Data Quality: -1 SON0: Sonic Anemometer #0 Instrument Status: -1 Data Continuity: 0 Data Quality: 1 SON1: Sonic Anemometer #1 Instrument Status: -1 Data Continuity: 0 Data Quality: 1 LICOR: Licor Measurements Instrument Status: -1 Data Continuity: 0 Data Quality: 1 TOWERMET: Flux Tower Meteorological Measurements Instrument Status: -1 Data Continuity: -1 Data Quality: -1 DMS: Data Management System ------------------------------------------------------------ --------------- ERROR SUMMARIES --------------- MMCR: Instrument Status: 1 20133460200Health.txt: 2GHzPhaseLock 0=TTL lo: 2/10 out of range ( 0.90 to 1.10), Mean: 0.80, StdDev: 0.42 20133460300Health.txt: 2GHzPhaseLock 0=TTL lo: 2/10 out of range ( 0.90 to 1.10), Mean: 0.80, StdDev: 0.42 20133460400Health.txt: 2GHzPhaseLock 0=TTL lo: 4/10 out of range ( 0.90 to 1.10), Mean: 0.60, StdDev: 0.52 20133460500Health.txt: 2GHzPhaseLock 0=TTL lo: 6/10 out of range ( 0.90 to 1.10), Mean: 0.40, StdDev: 0.52 20133460600Health.txt: 2GHzPhaseLock 0=TTL lo: 7/10 out of range ( 0.90 to 1.10), Mean: 0.30, StdDev: 0.48 20133460700Health.txt: 2GHzPhaseLock 0=TTL lo: 5/10 out of range ( 0.90 to 1.10), Mean: 0.50, StdDev: 0.53 20133460800Health.txt: 2GHzPhaseLock 0=TTL lo: 2/10 out of range ( 0.90 to 1.10), Mean: 0.80, StdDev: 0.42 20133461000Health.txt: 2GHzPhaseLock 0=TTL lo: 1/10 out of range ( 0.90 to 1.10), Mean: 0.90, StdDev: 0.32 20133461200Health.txt: 2GHzPhaseLock 0=TTL lo: 2/10 out of range ( 0.90 to 1.10), Mean: 0.80, StdDev: 0.42 20133461300Health.txt: 2GHzPhaseLock 0=TTL lo: 2/10 out of range ( 0.90 to 1.10), Mean: 0.80, StdDev: 0.42 20133461400Health.txt: 2GHzPhaseLock 0=TTL lo: 1/10 out of range ( 0.90 to 1.10), Mean: 0.90, StdDev: 0.32 20133461500Health.txt: 2GHzPhaseLock 0=TTL lo: 1/10 out of range ( 0.90 to 1.10), Mean: 0.90, StdDev: 0.32 20133461800Health.txt: 2GHzPhaseLock 0=TTL lo: 4/10 out of range ( 0.90 to 1.10), Mean: 0.60, StdDev: 0.52 20133461800Health.txt: UPSOutputVoltage: 1/120 out of range (114.00 to 126.00), Mean: 117.18, StdDev: 10.90 20133461800Health.txt: UPSOutputCurrent: 1/120 out of range ( 0.00 to 10.00), Mean: 5.84, StdDev: 0.65 20133462300Health.txt: UPSOutputCurrent: 1/120 out of range ( 0.00 to 10.00), Mean: 5.84, StdDev: 0.65 MMCR: Data Continuity: 1 Data recovery: 95.8% MWR: Data Continuity: 2 Data recovery: 99.9% MWR: Data Quality: 1 TB_30.000: 5554/5683 out of range [0-300 K] SONIC0: Data Continuity: 0 Data recovery: 1.0% SONIC0: Data Quality: 1 U: 1792/6392 out of range [-40 to 40 m/s] W: 5943/6392 out of range [-20 to 20 m/s] Tv: 6392/6392 out of range [-60 to 30 m/s] SONIC1: Data Continuity: 0 Data recovery: 2.6% SONIC1: Data Quality: 1 W: 18543/18543 out of range [-20 to 20 m/s] Tv: 18543/18543 out of range [-60 to 30 m/s] LICOR: Data Continuity: 0 Data recovery: 3.9% LICOR: Data Quality: 1 CO2: 3/33422 out of range [0 to 1000 m/s] H2O: 33418/33422 out of range [0 to 1000 m/s] Pres: 33422/33422 out of range [900 to 1100 mb] ---------------------------------------------------------