eurqclog.20140722.000000.txt Data Quality Summary for Eureka SEARCH Research Station Summary created: Wed Jul 23 08:11:39 2014 Value Interpretation -1: No assessment preformed. 0: All values out of range. 1: Some values in and out of range. 2: All data present and all values in range. ----------------------------------------------------------- STATUS FLAGS ----------------------------------------------------------- MMCR: Millimeter Cloud Radar Instrument Status: 1 Data Continuity: 1 Data Quality: -1 MWR: Microwave Radiometer Instrument Status: 1 Data Continuity: 2 Data Quality: 1 AHSRL: Arctic High Spectral Resolution Lidar Instrument Status: -1 Data Continuity: -1 Data Quality: -1 PAERI: Polar Atmos. Emitted Radiance Interferometer Instrument Status: -1 Data Continuity: -1 Data Quality: -1 SON0: Sonic Anemometer #0 Instrument Status: -1 Data Continuity: 2 Data Quality: 2 SON1: Sonic Anemometer #1 Instrument Status: -1 Data Continuity: 1 Data Quality: 2 LICOR: Licor Measurements Instrument Status: -1 Data Continuity: 1 Data Quality: 1 TOWERMET: Flux Tower Meteorological Measurements Instrument Status: -1 Data Continuity: -1 Data Quality: -1 DMS: Data Management System ------------------------------------------------------------ --------------- ERROR SUMMARIES --------------- MMCR: Instrument Status: 1 20142030500Health.txt: UPSInputVoltage : 1/120 out of range (108.00 to 126.00), Mean: 118.55, StdDev: 11.02 20142030500Health.txt: UPSOutputVoltage: 1/120 out of range (114.00 to 126.00), Mean: 116.58, StdDev: 10.85 20142030500Health.txt: UPSOutputCurrent: 1/120 out of range ( 0.00 to 10.00), Mean: 5.34, StdDev: 0.63 20142030500Health.txt: UPSBatteryVoltage: 1/120 out of range ( 24.00 to 58.00), Mean: 52.85, StdDev: 4.96 20142030600Health.txt: UPSBatteryVoltage: 1/120 out of range ( 24.00 to 58.00), Mean: 52.85, StdDev: 4.96 20142030700Health.txt: UPSBatteryVoltage: 1/120 out of range ( 24.00 to 58.00), Mean: 52.85, StdDev: 4.96 20142031300Health.txt: UPSOutputVoltage: 1/120 out of range (114.00 to 126.00), Mean: 116.69, StdDev: 10.85 20142031300Health.txt: UPSOutputCurrent: 1/120 out of range ( 0.00 to 10.00), Mean: 5.30, StdDev: 0.61 20142031900Health.txt: UPSInputVoltage : 2/120 out of range (108.00 to 126.00), Mean: 117.72, StdDev: 15.53 20142031900Health.txt: UPSOutputVoltage: 2/120 out of range (114.00 to 126.00), Mean: 115.57, StdDev: 15.25 20142031900Health.txt: UPSOutputCurrent: 2/120 out of range ( 0.00 to 10.00), Mean: 5.24, StdDev: 0.84 20142031900Health.txt: UPSBatteryVoltage: 1/120 out of range ( 24.00 to 58.00), Mean: 52.85, StdDev: 4.96 20142032000Health.txt: UPSBatteryVoltage: 1/120 out of range ( 24.00 to 58.00), Mean: 52.85, StdDev: 4.96 MMCR: Data Continuity: 1 Data recovery: 95.8% MWR: Instrument Status: 1 22.235 CAL: 2/47 out of range, [Tnd +/- 3K] 23.035 CAL: 1/47 out of range, [Tnd +/- 3K] 23.835 CAL: 18/47 out of range, [Tnd +/- 3K] 26.235 CAL: 40/47 out of range, [Tnd +/- 3K] 30.000 CAL: 47/47 out of range, [Tnd +/- 3K] MWR: Data Continuity: 2 Data recovery: 99.9% MWR: Data Quality: 1 TB_30.000: 5186/5683 out of range [0-300 K] SONIC0: Data Continuity: 2 Data recovery: 100.0% SONIC1: Data Continuity: 1 Data recovery: 95.8% LICOR: Data Continuity: 1 Data recovery: 95.8% LICOR: Data Quality: 1 H2O: 8016/827981 out of range [0 to 1000 m/s] Temp: 35/827981 out of range [-60 to 30 m/s] Pres: 1346/827981 out of range [900 to 1100 mb] ---------------------------------------------------------