30-jul-10 01:55:00 Measurements ended --- . Number of lamps (L) = 7 . Filter running time = 17.83 hours . Total airflow this filter = 5.26 cubic meters . Mean BC concentration of all lamps = 97 ng/m3 . Report for lamp 1 (370 nm): . Ending voltages: sen(beam) = .473 sen(zero) = 0.021 . ref(beam) = 1.398 ref(zero) = 0.020 . Optical attenuation of filter deposit = 75 . Total aerosol black carbon on filter = 953 ng Mean aerosol black carbon concentration = 181 ng/m3 --- The reference beam showed lamp intensity fluctuations of 325 ppm. --- Report for lamp 2 (470 nm): . Ending voltages: sen(beam) = 1.123 sen(zero) = 0.021 . ref(beam) = 1.590 ref(zero) = 0.020 . Optical attenuation of filter deposit = 38 . Total aerosol black carbon on filter = 622 ng Mean aerosol black carbon concentration = 118 ng/m3 --- The reference beam showed lamp intensity fluctuations of 62 ppm. --- Report for lamp 3 (520 nm): . Ending voltages: sen(beam) = 1.221 sen(zero) = 0.021 . ref(beam) = 2.029 ref(zero) = 0.020 . Optical attenuation of filter deposit = 28 . Total aerosol black carbon on filter = 500 ng Mean aerosol black carbon concentration = 95 ng/m3 --- The reference beam showed lamp intensity fluctuations of 39 ppm. --- Report for lamp 4 (590 nm): . Ending voltages: sen(beam) = 1.202 sen(zero) = 0.021 . ref(beam) = 2.802 ref(zero) = 0.020 . Optical attenuation of filter deposit = 22 . Total aerosol black carbon on filter = 451 ng Mean aerosol black carbon concentration = 86 ng/m3 --- The reference beam showed lamp intensity fluctuations of 245 ppm. --- Report for lamp 5 (660 nm): . Ending voltages: sen(beam) = 1.806 sen(zero) = 0.021 . ref(beam) = 2.415 ref(zero) = 0.020 . Optical attenuation of filter deposit = 18 . Total aerosol black carbon on filter = 408 ng Mean aerosol black carbon concentration = 77 ng/m3 --- The reference beam showed lamp intensity fluctuations of 121 ppm. --- Report for lamp 6 (880 nm): . Ending voltages: sen(beam) = 1.605 sen(zero) = 0.021 . ref(beam) = 2.343 ref(zero) = 0.020 . Optical attenuation of filter deposit = 10 . Total aerosol black carbon on filter = 329 ng Mean aerosol black carbon concentration = 62 ng/m3 --- The reference beam showed lamp intensity fluctuations of 175 ppm. --- Report for lamp 7 (950 nm): . Ending voltages: sen(beam) = 1.446 sen(zero) = 0.021 . ref(beam) = 2.267 ref(zero) = 0.020 . Optical attenuation of filter deposit = 9 . Total aerosol black carbon on filter = 305 ng Mean aerosol black carbon concentration = 58 ng/m3 --- The reference beam showed lamp intensity fluctuations of 186 ppm. --- Disk space = 2.516828E+08 bytes free: One entry at every 5 minutes. There is space for 53504 hours ( 2229 days) more data --- 30-jul-10 01:55:00 Tape feeder mechanism advancing for 1 spot(s). --- ============================================================= --- MAGEE SCIEN. AETHALOMETER --- Aethalometer No. 774 --- 30-jul-10 02:04:56 Measurements started Starting voltages: . sen(zero) = 0.021 ref(zero) = 0.020 . Lamp 1 (370 nm): sen(beam) = .907 ref(beam) = 1.349 . Lamp 2 (470 nm): sen(beam) = 1.646 ref(beam) = 1.605 . Lamp 3 (520 nm): sen(beam) = 1.617 ref(beam) = 2.057 . Lamp 4 (590 nm): sen(beam) = 1.471 ref(beam) = 2.781 . Lamp 5 (660 nm): sen(beam) = 2.165 ref(beam) = 2.429 . Lamp 6 (880 nm): sen(beam) = 1.796 ref(beam) = 2.367 . Lamp 7 (950 nm): sen(beam) = 1.598 ref(beam) = 2.289 ---