15-sep-11 01:36:56 Measurements ended --- . Number of lamps (L) = 7 . Filter running time = 34.41 hours . Total airflow this filter = 10.17 cubic meters . Mean BC concentration of all lamps = 99 ng/vm3 . Report for lamp 1 (370 nm): . Ending voltages: sen(beam) = .200 sen(zero) = 0.021 . ref(beam) = 1.479 ref(zero) = 0.020 . Optical attenuation of filter deposit = 42 . Total aerosol black carbon on filter = 539 ng Mean aerosol black carbon concentration = 53 ng/vm3 --- The reference beam showed lamp intensity fluctuations of 118 ppm. --- Report for lamp 2 (470 nm): . Ending voltages: sen(beam) = .221 sen(zero) = 0.021 . ref(beam) = 1.701 ref(zero) = 0.020 . Optical attenuation of filter deposit = 73 . Total aerosol black carbon on filter = 1178 ng Mean aerosol black carbon concentration = 116 ng/vm3 --- The reference beam showed lamp intensity fluctuations of 29 ppm. --- Report for lamp 3 (520 nm): . Ending voltages: sen(beam) = .357 sen(zero) = 0.021 . ref(beam) = 2.109 ref(zero) = 0.020 . Optical attenuation of filter deposit = 20 . Total aerosol black carbon on filter = 360 ng Mean aerosol black carbon concentration = 35 ng/vm3 --- The reference beam showed lamp intensity fluctuations of 29 ppm. --- Report for lamp 4 (590 nm): . Ending voltages: sen(beam) = .422 sen(zero) = 0.021 . ref(beam) = 3.208 ref(zero) = 0.020 . Optical attenuation of filter deposit = 49 . Total aerosol black carbon on filter = 1001 ng Mean aerosol black carbon concentration = 98 ng/vm3 --- The reference beam showed lamp intensity fluctuations of 96 ppm. --- Report for lamp 5 (660 nm): . Ending voltages: sen(beam) = .619 sen(zero) = 0.021 . ref(beam) = 2.430 ref(zero) = 0.020 . Optical attenuation of filter deposit = 52 . Total aerosol black carbon on filter = 1177 ng Mean aerosol black carbon concentration = 116 ng/vm3 --- The reference beam showed lamp intensity fluctuations of 51 ppm. --- Report for lamp 6 (880 nm): . Ending voltages: sen(beam) = .725 sen(zero) = 0.021 . ref(beam) = 2.612 ref(zero) = 0.020 . Optical attenuation of filter deposit = 42 . Total aerosol black carbon on filter = 1283 ng Mean aerosol black carbon concentration = 126 ng/vm3 --- The reference beam showed lamp intensity fluctuations of 75 ppm. --- Report for lamp 7 (950 nm): . Ending voltages: sen(beam) = .606 sen(zero) = 0.021 . ref(beam) = 2.576 ref(zero) = 0.020 . Optical attenuation of filter deposit = 48 . Total aerosol black carbon on filter = 1558 ng Mean aerosol black carbon concentration = 153 ng/vm3 --- The reference beam showed lamp intensity fluctuations of 75 ppm. --- Disk space = 2.507244E+08 bytes free: One entry at every 5 minutes. There is space for 53300 hours ( 2221 days) more data --- 15-sep-11 01:48:27 Tape feeder mechanism advancing for 1 spot(s). --- Disk space = 2.505523E+08 bytes free: One entry at every 5 minutes. There is space for 53264 hours ( 2219 days) more data --- 15-sep-11 01:50:58 Tape feeder mechanism advancing for 1 spot(s). --- 15-sep-11 01:55:37 ============================================================= Automatic re-start ============================================================= --- MAGEE SCIEN. AETHALOMETER --- Aethalometer No. 774 --- 15-sep-11 01:59:56 Measurements started Starting voltages: . sen(zero) = 0.021 ref(zero) = 0.020 . Lamp 1 (370 nm): sen(beam) = .211 ref(beam) = 1.100 . Lamp 2 (470 nm): sen(beam) = .348 ref(beam) = 1.620 . Lamp 3 (520 nm): sen(beam) = .852 ref(beam) = 1.574 . Lamp 4 (590 nm): sen(beam) = .779 ref(beam) = 2.629 . Lamp 5 (660 nm): sen(beam) = .606 ref(beam) = 2.419 . Lamp 6 (880 nm): sen(beam) = .435 ref(beam) = 1.949 . Lamp 7 (950 nm): sen(beam) = .291 ref(beam) = 2.246 ---