Monitor statistics generated at: 20082182200 (YYYYJJJHHMM) Parameter Name Mean StdDev Count LoLimit HiLimit In Out interface box (#1) +5V 4.99 0.00 9 4.75 5.25 9 0 interface box (#2) +5V 4.95 0.00 9 4.75 5.25 9 0 interface box +28V 27.84 0.02 9 26.60 29.40 9 0 interface box +15V 12.02 0.02 9 11.50 12.50 9 0 interface box -15V -11.96 0.02 9 -12.50 -11.50 9 0 rf cud +15V 14.89 0.00 9 14.25 15.75 9 0 rf cud tx +12V 11.91 0.00 9 11.40 12.60 9 0 rf cud rx +12V 11.59 0.03 9 11.40 12.60 9 0 if rec/mod +12V 11.91 0.00 9 11.40 12.60 9 0 if rec/mod +15V 14.91 0.03 9 14.25 15.75 9 0 2GHzPhaseLock 0=TTL lo 1.00 0.00 9 0.90 1.10 9 0 16GHzPhaseLock TTL lo 1.00 0.00 9 0.90 1.10 9 0 temperature (outdoor) 323.39 0.61 29 0.00 100.00 0 29 temperature (indoor) 23.22 0.76 29 21.00 29.00 29 0 humidity (indoor) 22.90 0.46 29 15.00 75.00 29 0 temperature (circ #1) 56.53 0.30 29 0.00 50.00 0 29 UPSInputVoltage 115.92 0.38 116 114.00 126.00 116 0 UPSOutputVoltage 121.71 0.09 116 114.00 126.00 116 0 UPSOutputCurrent 4.92 0.13 116 0.00 5.70 116 0 UPSBatteryVoltage 13.55 0.01 116 14.00 14.90 0 116 TransmittedRFPower 51.47 26.64 3478 47.00 53.00 3478 0 Transmitted RF Power History Past 10/100/1000 Hours: 51.44/ 51.13/ 49.65 TWTA attempted restarts (5 min thru 55 min) =0/0/0/0/0/0