Monitor statistics generated at: 20082371300 (YYYYJJJHHMM) Parameter Name Mean StdDev Count LoLimit HiLimit In Out interface box (#1) +5V 4.99 0.00 9 4.75 5.25 9 0 interface box (#2) +5V 4.95 0.00 9 4.75 5.25 9 0 interface box +28V 27.83 0.00 9 26.60 29.40 9 0 interface box +15V 12.03 0.02 9 11.50 12.50 9 0 interface box -15V -11.96 0.00 9 -12.50 -11.50 9 0 rf cud +15V 14.89 0.02 9 14.25 15.75 9 0 rf cud tx +12V 11.92 0.02 9 11.40 12.60 9 0 if rec/mod +12V 11.91 0.00 9 11.40 12.60 9 0 if rec/mod +15V 14.90 0.02 9 14.25 15.75 9 0 2GHzPhaseLock 0=TTL lo 1.00 0.00 9 0.90 1.10 9 0 16GHzPhaseLock TTL lo 1.00 0.00 9 0.90 1.10 9 0 temperature (outdoor) 0.84 0.37 29 -50.00 50.00 29 0 temperature (indoor) 26.24 0.89 29 5.00 35.00 29 0 humidity (indoor) 18.00 0.76 29 -1.00 95.00 29 0 temperature (circ #1) 57.51 0.29 29 0.00 60.00 29 0 UPSInputVoltage NaN 0.00 0 114.00 126.00 0 0 UPSOutputVoltage NaN 0.00 0 114.00 126.00 0 0 UPSOutputCurrent NaN 0.00 0 0.00 5.70 0 0 UPSBatteryVoltage NaN 0.00 0 13.25 14.50 0 0 TransmittedRFPower 51.47 28.61 3521 49.00 54.00 3501 20 Transmitted RF Power History Past 10/100/1000 Hours: 51.51/ 51.48/ 50.28 TWTA attempted restarts (5 min thru 55 min) =0/0/0/0/0/0 ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 08/24/08 12:30:06 Daily RF Calibration - CalTable Set = 0 - Passed 08/24/08 12:30:08 Daily RF Calibration - CalTable Set = 1 - Passed 08/24/08 12:30:11 Daily RF Calibration - CalTable Set = 2 - Passed 08/24/08 12:30:12 Daily RF Calibration - CalTable Set = 3 - Passed