Monitor statistics generated at: 20082491300 (YYYYJJJHHMM) Parameter Name Mean StdDev Count LoLimit HiLimit In Out interface box (#1) +5V 5.02 0.00 8 4.75 5.25 8 0 interface box (#2) +5V 4.99 0.00 8 4.75 5.25 8 0 interface box +28V 27.99 0.02 8 26.60 29.40 8 0 interface box +15V 12.11 0.00 8 11.50 12.50 8 0 interface box -15V -12.06 0.00 8 -12.50 -11.50 8 0 rf cud +15V 14.98 0.02 8 14.25 15.75 8 0 rf cud tx +12V 12.00 0.02 8 11.40 12.60 8 0 if rec/mod +12V 11.96 0.00 8 11.40 12.60 8 0 if rec/mod +15V 14.99 0.00 8 14.25 15.75 8 0 2GHzPhaseLock 0=TTL lo 1.00 0.00 8 0.90 1.10 8 0 16GHzPhaseLock TTL lo 1.00 0.00 8 0.90 1.10 8 0 temperature (outdoor) 4.50 0.35 24 -50.00 50.00 24 0 temperature (indoor) 27.08 0.76 24 5.00 35.00 24 0 humidity (indoor) 21.00 0.64 24 -1.00 95.00 24 0 temperature (circ #1) 57.92 0.25 24 0.00 60.00 24 0 UPSInputVoltage NaN 0.00 0 114.00 126.00 0 0 UPSOutputVoltage NaN 0.00 0 114.00 126.00 0 0 UPSOutputCurrent NaN 0.00 0 0.00 5.70 0 0 UPSBatteryVoltage NaN 0.00 0 13.25 14.50 0 0 TransmittedRFPower 51.53 27.14 2864 49.00 54.00 2844 20 Transmitted RF Power History Past 10/100/1000 Hours: 51.48/ 51.53/ 51.02 TWTA attempted restarts (5 min thru 55 min) =0/0/0/0/0/0 ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 09/05/08 12:30:04 Daily RF Calibration - CalTable Set = 0 - Passed 09/05/08 12:30:05 Daily RF Calibration - CalTable Set = 1 - Passed 09/05/08 12:30:08 Daily RF Calibration - CalTable Set = 2 - Passed 09/05/08 12:30:09 Daily RF Calibration - CalTable Set = 3 - Passed