Monitor statistics generated at:  20140760916  (YYYYJJJHHMM)
Parameter Name		  Mean	 StdDev	 Count	LoLimit	HiLimit	  In	  Out
power supply   +5VDC	  5.13	  0.00	   3	  4.75	  5.25	   3	   0
power supply -5.2VDC	 -5.23	  0.00	   3	 -5.50	 -4.75	   3	   0
power supply  +28VDC	 27.98	  0.00	   3	 26.60	 29.40	   3	   0
power supply  +15VDC	 15.38	  0.00	   3	 14.50	 15.50	   3	   0
power supply  -15VDC	-15.33	  0.00	   3	-15.50	-14.50	   3	   0
spacek supply  +5VDC	  5.00	  0.00	   3	  4.75	  5.25	   3	   0
spacek supply +12VDC	 12.03	  0.03	   3	 11.75	 12.25	   3	   0
2.1 GHzPhaseLock (TTL)	  1.00	  0.00	   3	  0.90	  1.10	   3	   0
15.4 GHzPhaseLock (TTL)	  1.00	  0.00	   3	  0.90	  1.10	   3	   0
SW fault      (TTL)	  1.00	  0.00	   3	  0.90	  1.10	   3	   0
Pulse fault   (TTL)	  1.00	  0.00	   3	  0.90	  1.10	   3	   0
temperature  (indoor)	 61.02	  0.66	   9	  5.00	 35.00	   0	   9
temperature (warm load)	 55.83	  0.73	   9	-50.00	 50.00	   0	   9
temperature  (RF plate)	 60.60	  0.51	   9	-50.00	 50.00	   0	   9
UPSInputVoltage 	   NaN	  0.00	   0	114.00	126.00	   0	   0
UPSOutputVoltage	   NaN	  0.00	   0	114.00	126.00	   0	   0
UPSOutputCurrent	   NaN	  0.00	   0	  0.00	  5.70	   0	   0
UPSBatteryVoltage	   NaN	  0.00	   0	 13.25	 14.50	   0	   0
TransmittedRFPower	 62.39	 41.35	3600	 57.00	 63.00	3009	 591

Transmitted RF Power History Past 10/100/1000 Hours:   62.40/  62.10/  61.25
TWTA attempted restarts (5 min thru 55 min) =0/0/0/0/0/0