Monitor statistics generated at: 20140891300 (YYYYJJJHHMM) Parameter Name Mean StdDev Count LoLimit HiLimit In Out power supply +5VDC 5.13 0.00 14 4.75 5.25 14 0 power supply -5.2VDC -5.23 0.00 14 -5.50 -4.75 14 0 power supply +28VDC 27.97 0.02 14 26.60 29.40 14 0 power supply +15VDC 15.38 0.01 14 14.50 15.50 14 0 power supply -15VDC -15.33 0.01 14 -15.50 -14.50 14 0 spacek supply +5VDC 5.00 0.00 14 4.75 5.25 14 0 spacek supply +12VDC 12.04 0.04 14 11.75 12.25 14 0 2.1 GHzPhaseLock (TTL) 1.00 0.00 14 0.90 1.10 14 0 15.4 GHzPhaseLock (TTL) 1.00 0.00 14 0.90 1.10 14 0 SW fault (TTL) 1.00 0.00 14 0.90 1.10 14 0 Pulse fault (TTL) 1.00 0.00 14 0.90 1.10 14 0 temperature (indoor) 63.96 18.05 42 5.00 35.00 0 42 temperature (warm load) 61.84 31.68 42 -50.00 50.00 0 42 temperature (RF plate) 68.12 36.63 42 -50.00 50.00 0 42 UPSInputVoltage NaN 0.00 0 114.00 126.00 0 0 UPSOutputVoltage NaN 0.00 0 114.00 126.00 0 0 UPSOutputCurrent NaN 0.00 0 0.00 5.70 0 0 UPSBatteryVoltage NaN 0.00 0 13.25 14.50 0 0 TransmittedRFPower 62.22 40.89 5008 57.00 63.00 4019 989 Transmitted RF Power History Past 10/100/1000 Hours: 62.23/ 62.23/ 61.65 TWTA attempted restarts (5 min thru 55 min) =0/0/0/0/0/0