Monitor statistics generated at: 20140960400 (YYYYJJJHHMM) Parameter Name Mean StdDev Count LoLimit HiLimit In Out power supply +5VDC 5.13 0.00 10 4.75 5.25 10 0 power supply -5.2VDC -5.22 0.00 10 -5.50 -4.75 10 0 power supply +28VDC 27.98 0.00 10 26.60 29.40 10 0 power supply +15VDC 15.41 0.03 10 14.50 15.50 10 0 power supply -15VDC -15.33 0.00 10 -15.50 -14.50 10 0 spacek supply +5VDC 5.00 0.00 10 4.75 5.25 10 0 spacek supply +12VDC 12.03 0.03 10 11.75 12.25 10 0 2.1 GHzPhaseLock (TTL) 1.00 0.00 10 0.90 1.10 10 0 15.4 GHzPhaseLock (TTL) 1.00 0.00 10 0.90 1.10 10 0 SW fault (TTL) 1.00 0.00 10 0.90 1.10 10 0 Pulse fault (TTL) 1.00 0.00 10 0.90 1.10 10 0 temperature (indoor) 60.60 0.81 30 5.00 35.00 0 30 temperature (warm load) 56.43 0.86 30 -50.00 50.00 0 30 temperature (RF plate) 62.26 0.74 30 -50.00 50.00 0 30 UPSInputVoltage NaN 0.00 0 114.00 126.00 0 0 UPSOutputVoltage NaN 0.00 0 114.00 126.00 0 0 UPSOutputCurrent NaN 0.00 0 0.00 5.70 0 0 UPSBatteryVoltage NaN 0.00 0 13.25 14.50 0 0 TransmittedRFPower 62.33 35.39 3600 57.00 63.00 2872 728 Transmitted RF Power History Past 10/100/1000 Hours: 62.33/ 62.27/ 61.76 TWTA attempted restarts (5 min thru 55 min) =0/0/0/0/0/0