Monitor statistics generated at: 20140960800 (YYYYJJJHHMM) Parameter Name Mean StdDev Count LoLimit HiLimit In Out power supply +5VDC 5.13 0.00 12 4.75 5.25 12 0 power supply -5.2VDC -5.22 0.00 12 -5.50 -4.75 12 0 power supply +28VDC 27.97 0.03 12 26.60 29.40 12 0 power supply +15VDC 15.40 0.03 12 14.50 15.50 12 0 power supply -15VDC -15.33 0.01 12 -15.50 -14.50 12 0 spacek supply +5VDC 5.00 0.00 12 4.75 5.25 12 0 spacek supply +12VDC 12.05 0.05 12 11.75 12.25 12 0 2.1 GHzPhaseLock (TTL) 1.00 0.00 12 0.90 1.10 12 0 15.4 GHzPhaseLock (TTL) 1.00 0.00 12 0.90 1.10 12 0 SW fault (TTL) 1.00 0.00 12 0.90 1.10 12 0 Pulse fault (TTL) 1.00 0.00 12 0.90 1.10 12 0 temperature (indoor) 60.60 0.81 34 5.00 35.00 0 34 temperature (warm load) 55.87 1.02 34 -50.00 50.00 0 34 temperature (RF plate) 62.16 0.61 34 -50.00 50.00 0 34 UPSInputVoltage NaN 0.00 0 114.00 126.00 0 0 UPSOutputVoltage NaN 0.00 0 114.00 126.00 0 0 UPSOutputCurrent NaN 0.00 0 0.00 5.70 0 0 UPSBatteryVoltage NaN 0.00 0 13.25 14.50 0 0 TransmittedRFPower 62.33 31.24 4045 57.00 63.00 3239 806 Transmitted RF Power History Past 10/100/1000 Hours: 62.33/ 62.27/ 61.76 TWTA attempted restarts (5 min thru 55 min) =0/0/0/0/0/0