Monitor statistics generated at: 20112980004 (YYYYJJJHHMM) Parameter Name Mean StdDev Count LoLimit HiLimit In Out power supply +5VDC NaN 0.00 0 4.75 5.25 0 0 power supply -5.2VDC NaN 0.00 0 -5.50 -4.75 0 0 power supply +28VDC NaN 0.00 0 26.60 29.40 0 0 power supply +15VDC NaN 0.00 0 14.50 15.50 0 0 power supply -15VDC NaN 0.00 0 -15.50 -14.50 0 0 spacek supply +5VDC NaN 0.00 0 4.75 5.25 0 0 spacek supply +12VDC NaN 0.00 0 11.75 12.25 0 0 2.1 GHzPhaseLock (TTL) NaN 0.00 0 0.90 1.10 0 0 15.4 GHzPhaseLock (TTL) NaN 0.00 0 0.90 1.10 0 0 SW fault (TTL) NaN 0.00 0 0.90 1.10 0 0 Pulse fault (TTL) NaN 0.00 0 0.90 1.10 0 0 temperature (indoor) 59.09 0.33 2 5.00 35.00 0 2 temperature (warm load) 54.44 0.35 2 -50.00 50.00 0 2 temperature (RF plate) 60.55 0.69 2 -50.00 50.00 0 2 UPSInputVoltage NaN 0.00 0 114.00 126.00 0 0 UPSOutputVoltage NaN 0.00 0 114.00 126.00 0 0 UPSOutputCurrent NaN 0.00 0 0.00 5.70 0 0 UPSBatteryVoltage NaN 0.00 0 13.25 14.50 0 0 TransmittedRFPower 61.30 44.08 3536 57.00 63.00 1811 1725 Transmitted RF Power History Past 10/100/1000 Hours: 61.31/ 61.30/ 61.33 TWTA attempted restarts (5 min thru 55 min) =0/0/0/0/0/0