Monitor statistics generated at: 20113171000 (YYYYJJJHHMM) Parameter Name Mean StdDev Count LoLimit HiLimit In Out power supply +5VDC 5.04 0.00 11 4.75 5.25 11 0 power supply -5.2VDC -5.22 0.00 11 -5.50 -4.75 11 0 power supply +28VDC 27.93 0.01 11 26.60 29.40 11 0 power supply +15VDC 15.33 0.00 11 14.50 15.50 11 0 power supply -15VDC -15.28 0.00 11 -15.50 -14.50 11 0 spacek supply +5VDC 5.00 0.00 11 4.75 5.25 11 0 spacek supply +12VDC 12.02 0.02 11 11.75 12.25 11 0 2.1 GHzPhaseLock (TTL) 1.00 0.00 11 0.90 1.10 11 0 15.4 GHzPhaseLock (TTL) 1.00 0.00 11 0.90 1.10 11 0 SW fault (TTL) 1.00 0.00 11 0.90 1.10 11 0 Pulse fault (TTL) 1.00 0.00 11 0.90 1.10 11 0 temperature (indoor) 59.59 0.83 34 5.00 35.00 0 34 temperature (warm load) 54.92 0.93 34 -50.00 50.00 0 34 temperature (RF plate) 61.81 0.90 34 -50.00 50.00 0 34 UPSInputVoltage NaN 0.00 0 114.00 126.00 0 0 UPSOutputVoltage NaN 0.00 0 114.00 126.00 0 0 UPSOutputCurrent NaN 0.00 0 0.00 5.70 0 0 UPSBatteryVoltage NaN 0.00 0 13.25 14.50 0 0 TransmittedRFPower 60.66 42.05 4182 57.00 63.00 2240 1942 Transmitted RF Power History Past 10/100/1000 Hours: 60.71/ 60.72/ 61.20 TWTA attempted restarts (5 min thru 55 min) =0/0/0/0/0/0