Monitor statistics generated at: 20113181900 (YYYYJJJHHMM) Parameter Name Mean StdDev Count LoLimit HiLimit In Out power supply +5VDC 5.04 0.00 9 4.75 5.25 9 0 power supply -5.2VDC -5.22 0.00 9 -5.50 -4.75 9 0 power supply +28VDC 27.93 0.00 9 26.60 29.40 9 0 power supply +15VDC 15.32 0.02 9 14.50 15.50 9 0 power supply -15VDC -15.29 0.02 9 -15.50 -14.50 9 0 spacek supply +5VDC 5.00 0.00 9 4.75 5.25 9 0 spacek supply +12VDC 12.03 0.02 9 11.75 12.25 9 0 2.1 GHzPhaseLock (TTL) 1.00 0.00 9 0.90 1.10 9 0 15.4 GHzPhaseLock (TTL) 1.00 0.00 9 0.90 1.10 9 0 SW fault (TTL) 1.00 0.00 9 0.90 1.10 9 0 Pulse fault (TTL) 1.00 0.00 9 0.90 1.10 9 0 temperature (indoor) 60.06 0.64 29 5.00 35.00 0 29 temperature (warm load) 55.19 0.91 29 -50.00 50.00 0 29 temperature (RF plate) 61.83 0.75 29 -50.00 50.00 0 29 UPSInputVoltage NaN 0.00 0 114.00 126.00 0 0 UPSOutputVoltage NaN 0.00 0 114.00 126.00 0 0 UPSOutputCurrent NaN 0.00 0 0.00 5.70 0 0 UPSBatteryVoltage NaN 0.00 0 13.25 14.50 0 0 TransmittedRFPower 60.71 44.71 3536 57.00 63.00 1862 1674 Transmitted RF Power History Past 10/100/1000 Hours: 60.69/ 60.70/ 61.18 TWTA attempted restarts (5 min thru 55 min) =0/0/0/0/0/0