Monitor statistics generated at: 20080860100 (YYYYJJJHHMM) Parameter Name Mean StdDev Count LoLimit HiLimit In Out interface box (#1) +5V 5.02 0.00 9 4.75 5.25 9 0 interface box (#2) +5V 4.99 0.00 9 4.75 5.25 9 0 interface box +28V 28.03 0.00 9 26.60 29.40 9 0 interface box +15V 12.12 0.02 9 11.50 12.50 9 0 interface box -15V -12.07 0.02 9 -12.50 -11.50 9 0 rf cud +15V 14.99 0.00 9 14.25 15.75 9 0 rf cud tx +12V 12.00 0.02 9 11.40 12.60 9 0 if rec/mod +12V 11.98 0.03 9 11.40 12.60 9 0 if rec/mod +15V 15.02 0.03 9 14.25 15.75 9 0 2GHzPhaseLock 0=TTL lo 1.00 0.00 9 0.90 1.10 9 0 16GHzPhaseLock TTL lo 1.00 0.00 9 0.90 1.10 9 0 temperature (outdoor) 13.15 1.22 29 -50.00 50.00 29 0 temperature (indoor) 30.91 0.97 29 5.00 35.00 29 0 humidity (indoor) 27.63 2.28 29 -1.00 95.00 29 0 temperature (circ #1) 56.89 0.53 29 0.00 50.00 0 29 UPSInputVoltage 115.90 0.06 117 114.00 126.00 117 0 UPSOutputVoltage 121.27 0.07 117 114.00 126.00 117 0 UPSOutputCurrent 4.74 0.16 117 0.00 5.70 117 0 UPSBatteryVoltage 13.54 0.01 117 13.25 14.50 117 0 TransmittedRFPower 52.98 33.60 3486 49.00 54.00 3467 19 Transmitted RF Power History Past 10/100/1000 Hours: 52.95/ 52.94/ 52.90 TWTA attempted restarts (5 min thru 55 min) =0/0/0/0/0/0