Monitor statistics generated at: 20081071000 (YYYYJJJHHMM) Parameter Name Mean StdDev Count LoLimit HiLimit In Out interface box (#1) +5V 4.99 0.00 9 4.75 5.25 9 0 interface box (#2) +5V 4.96 0.00 9 4.75 5.25 9 0 interface box +28V 27.83 0.00 9 26.60 29.40 9 0 interface box +15V 12.02 0.02 9 11.50 12.50 9 0 interface box -15V -11.96 0.00 9 -12.50 -11.50 9 0 rf cud +15V 14.88 0.02 9 14.25 15.75 9 0 rf cud tx +12V 11.91 0.00 9 11.40 12.60 9 0 if rec/mod +12V 11.91 0.02 9 11.40 12.60 9 0 if rec/mod +15V 14.90 0.02 9 14.25 15.75 9 0 2GHzPhaseLock 0=TTL lo 1.00 0.00 9 0.90 1.10 9 0 16GHzPhaseLock TTL lo 1.00 0.00 9 0.90 1.10 9 0 temperature (outdoor) -9.47 0.52 30 -50.00 50.00 30 0 temperature (indoor) 20.73 1.02 30 5.00 35.00 30 0 humidity (indoor) 18.55 1.13 30 -1.00 95.00 30 0 temperature (circ #1) 57.00 0.49 30 0.00 60.00 30 0 UPSInputVoltage 116.13 0.10 120 114.00 126.00 120 0 UPSOutputVoltage 121.74 0.07 120 114.00 126.00 120 0 UPSOutputCurrent 4.70 0.13 120 0.00 5.70 120 0 UPSBatteryVoltage 13.55 0.01 120 13.25 14.50 120 0 TransmittedRFPower 53.20 28.21 3612 49.00 54.00 3611 1 Transmitted RF Power History Past 10/100/1000 Hours: 53.23/ 53.12/ 53.00 TWTA attempted restarts (5 min thru 55 min) =0/0/0/0/0/0