Monitor statistics generated at: 20081121800 (YYYYJJJHHMM) Parameter Name Mean StdDev Count LoLimit HiLimit In Out interface box (#1) +5V 4.99 0.00 9 4.75 5.25 9 0 interface box (#2) +5V 4.95 0.00 9 4.75 5.25 9 0 interface box +28V 27.78 0.00 9 26.60 29.40 9 0 interface box +15V 12.06 0.02 9 11.50 12.50 9 0 interface box -15V -11.96 0.00 9 -12.50 -11.50 9 0 rf cud +15V 14.89 0.00 9 14.25 15.75 9 0 rf cud tx +12V 11.91 0.00 9 11.40 12.60 9 0 if rec/mod +12V 11.89 0.03 9 11.40 12.60 9 0 if rec/mod +15V 14.91 0.03 9 14.25 15.75 9 0 2GHzPhaseLock 0=TTL lo 1.00 0.00 9 0.90 1.10 9 0 16GHzPhaseLock TTL lo 1.00 0.00 9 0.90 1.10 9 0 temperature (outdoor) 4.18 0.62 29 -50.00 50.00 29 0 temperature (indoor) 34.18 0.69 29 5.00 35.00 25 4 humidity (indoor) 9.24 0.43 29 -1.00 95.00 29 0 temperature (circ #1) 57.40 0.60 29 0.00 60.00 29 0 UPSInputVoltage 115.85 0.08 116 114.00 126.00 116 0 UPSOutputVoltage 121.61 0.07 116 114.00 126.00 116 0 UPSOutputCurrent 4.74 0.13 116 0.00 5.70 116 0 UPSBatteryVoltage 13.54 0.01 116 13.25 14.50 116 0 TransmittedRFPower 53.11 28.28 3479 49.00 54.00 3479 0 Transmitted RF Power History Past 10/100/1000 Hours: 53.11/ 53.10/ 53.03 TWTA attempted restarts (5 min thru 55 min) =0/0/0/0/0/0