Monitor statistics generated at: 20082791527 (YYYYJJJHHMM) Parameter Name Mean StdDev Count LoLimit HiLimit In Out power supply +5VDC 5.03 NaN 1 4.75 5.25 1 0 power supply -5.2VDC -5.24 NaN 1 -5.50 -4.75 1 0 power supply +28VDC 27.93 NaN 1 26.60 29.40 1 0 power supply +15VDC 15.23 NaN 1 14.50 15.50 1 0 power supply -15VDC -15.19 NaN 1 -15.50 -14.50 1 0 spacek supply +5VDC 0.00 NaN 1 4.75 5.25 0 1 spacek supply +12VDC 0.05 NaN 1 11.75 12.25 0 1 2.1 GHzPhaseLock (TTL) 0.00 NaN 1 0.90 1.10 0 1 15.4 GHzPhaseLock (TTL) 1.00 NaN 1 0.90 1.10 1 0 SW fault (TTL) 1.00 NaN 1 0.90 1.10 1 0 Pulse fault (TTL) 1.00 NaN 1 0.90 1.10 1 0 temperature (indoor) -34.61 0.33 2 5.00 35.00 0 2 temperature (warm load) -35.16 0.00 2 -50.00 50.00 2 0 temperature (RF plate) -23.68 0.35 2 -50.00 50.00 2 0 UPSInputVoltage 106.08 42.86 8 114.00 126.00 7 1 UPSOutputVoltage 106.05 42.85 8 114.00 126.00 7 1 UPSOutputCurrent 2.02 0.82 8 0.00 5.70 8 0 UPSBatteryVoltage 11.83 4.78 8 13.25 14.50 7 1 TransmittedRFPower 0.00 0.00 0 57.00 63.00 0 0 Transmitted RF Power History Past 10/100/1000 Hours: 62.44/ 60.88/ 51.46 TWTA attempted restarts (5 min thru 55 min) =0/0/0/0/0/0