Monitor statistics generated at: 20082830700 (YYYYJJJHHMM) Parameter Name Mean StdDev Count LoLimit HiLimit In Out power supply +5VDC 5.02 0.00 10 4.75 5.25 10 0 power supply -5.2VDC -5.24 0.00 10 -5.50 -4.75 10 0 power supply +28VDC 27.93 0.00 10 26.60 29.40 10 0 power supply +15VDC 15.20 0.02 10 14.50 15.50 10 0 power supply -15VDC -15.21 0.03 10 -15.50 -14.50 10 0 spacek supply +5VDC 5.01 0.00 10 4.75 5.25 10 0 spacek supply +12VDC 12.01 0.00 10 11.75 12.25 10 0 2.1 GHzPhaseLock (TTL) 1.00 0.00 10 0.90 1.10 10 0 15.4 GHzPhaseLock (TTL) 1.00 0.00 10 0.90 1.10 10 0 SW fault (TTL) 1.00 0.00 10 0.90 1.10 10 0 Pulse fault (TTL) 1.00 0.00 10 0.90 1.10 10 0 temperature (indoor) 57.30 0.41 30 5.00 35.00 0 30 temperature (warm load) 53.12 0.43 30 -50.00 50.00 0 30 temperature (RF plate) 52.59 0.53 30 -50.00 50.00 0 30 UPSInputVoltage 119.77 0.12 120 114.00 126.00 120 0 UPSOutputVoltage 120.31 0.07 120 114.00 126.00 120 0 UPSOutputCurrent 2.72 0.04 120 0.00 5.70 120 0 UPSBatteryVoltage 13.52 0.01 120 13.25 14.50 120 0 TransmittedRFPower NaN -Inf 3600 57.00 63.00 0 3600 Transmitted RF Power History Past 10/100/1000 Hours: 62.16/ 61.22/ 51.74 TWTA attempted restarts (5 min thru 55 min) =0/0/0/0/0/0